background image

9 Disposal

User reference guide

9

ADEA35~125A2VEB
Split system air conditioners
4P551388-1 – 2018.09

8.1.6

Symptom: The outdoor fan rotates while
the air conditioner is not in operation

After  operation  has  stopped.

  The  outdoor  fan  continues  to

rotate for another 30 seconds for system protection.

While the air conditioner is not in operation.

 When the outdoor

temperature  is  very  high,  the  outdoor  fan  starts  to  rotate  for
system protection.

8.1.7

Symptom: The heating operation stops
suddenly and a flowing sound is heard

The system is removing frost on the outdoor unit. You should wait for
about 3 to 8 minutes.

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

10

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Dealer

Sales distributor for the product.

Authorized installer

Technical  skilled  person  who  is  qualified  to  install  the
product.

User

Person  who  is  owner  of  the  product  and/or  operates  the
product.

Applicable legislation

All  international,  European,  national  and  local  directives,
laws,  regulations  and/or  codes  that  are  relevant  and
applicable for a certain product or domain.

Service company

Qualified  company  which  can  perform  or  coordinate  the
required service to the product.

Installation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to install, configure and maintain
it.

Operation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to operate it.

Accessories

Labels, manuals, information sheets and equipment that are
delivered  with  the  product  and  that  need  to  be  installed
according  to  the  instructions  in  the  accompanying
documentation.

Optional equipment

Equipment  made  or  approved  by  Daikin  that  can  be
combined  with  the  product  according  to  the  instructions  in
the accompanying documentation.

Field supply

Equipment NOT made by Daikin that can be combined with
the  product  according  to  the  instructions  in  the
accompanying documentation.

Summary of Contents for ADEA35A2VEB

Page 1: ...User reference guide Split system air conditioners English User reference guide Split system air conditioners ADEA35A2VEB ADEA50A2VEB ADEA60A2VEB ADEA71A2VEB ADEA100A2VEB ADEA125A2VEB...

Page 2: ...allation of the system and all activities described in the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANG...

Page 3: ...it User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product informa...

Page 4: ...CZECH REPUBLIC s r o U Nov Hospody 1 1155 301 00 Plze Skvr any Czech Republic A B C D E ADEA125A 7 83 4 27 13 50 0 35 62 3 3 User interface CAUTION NEVER touch the internal parts of the controller Do...

Page 5: ...sion instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of peop...

Page 6: ...be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fire Do NOT rinse the unit Do NOT operate the unit wi...

Page 7: ...tips and procedures for cleaning are provided in the installation operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position 7 6 Maintenance after a...

Page 8: ...lfunctions 8 1 1 Symptom The system does not operate The air conditioner does not start immediately after the ON OFF button on the user interface is pressed If the operation lamp lights the air condit...

Page 9: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Page 10: ......

Page 11: ......

Page 12: ...4P551388 1 2018 09 Copyright 2018 Daikin...

Reviews: