background image

4 Before operation

User reference guide

4

ADEA35~125A2VEB

Split system air conditioners

4P551388-1 – 2018.09

b

f

a

h

c

d

e

g

a

Indoor unit

b

Outdoor unit

c

User interface

d

Air inlet

e

Air outlet

f

Refrigerant piping and electric wiring

g

Drain pipe

h

Earth wire to ground outdoor unit to prevent electric
shocks.

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet  or  outlet.  Do  NOT  remove  the  fan  guard.  When  the
fan is rotating at high speed, it will cause injury.

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

NOTICE

Do  NOT  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

NOTICE

NEVER press the button of the user interface with a hard,
pointed object. The user interface may be damaged.

NOTICE

NEVER pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.

3.2

Information requirements for fan
coil units

Item

Symbol

Value

Unit

Cooling capacity (sensible)

P

rated,c

A

kW

Cooling capacity (latent)

P

rated,c

B

kW

Heating capacity

P

rated,h

C

kW

Total electric power input

P

elec

D

kW

Sound power level (per speed
setting, if applicable)

L

WA

E

dB

Contact details:

DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o. U Nové Hospody
1/1155, 301 00 Plzeň Skvrňany, Czech Republic

A

B

C

D

E

ADEA125A

7.83

4.27

13.50

0.35

62

3.3

User interface

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

This  operation  manual  will  give  a  non-exhaustive  overview  of  the
main functions of the system.

For  more  information  about  the  user  interface,  see  the  operation
manual of the installed user interface.

4

Before operation

WARNING

This unit contains electrical and hot parts.

WARNING

Before operating the unit, be sure the installation has been
carried out correctly by an installer.

CAUTION

It is not good for your health to expose your body to the air
flow for a long time.

CAUTION

To  avoid  oxygen  deficiency,  ventilate  the  room  sufficiently
if equipment with burner is used together with the system.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

NOTICE

Be  sure  to  turn  on  the  power  6  hours  before  operation  in
order  to  have  power  running  to  the  crankcase  heater  and
to protect the compressor.

5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

For  combination  with 

R410A  outdoor  unit

,  refer  to  the  following

table:

ARXS35~71

Cooling

Heating

Outdoor temperature

10~46°C DB

–15~18°C WB

Indoor temperature

14~28°C WB

10~30°C DB

Indoor humidity

≤80%

(a)

AZQS71~125

Cooling

Heating

Outdoor temperature

–5~46°C DB

–15~15.5°C WB

Indoor temperature

14~28°C WB

10~27°C DB

Summary of Contents for ADEA35A2VEB

Page 1: ...User reference guide Split system air conditioners English User reference guide Split system air conditioners ADEA35A2VEB ADEA50A2VEB ADEA60A2VEB ADEA71A2VEB ADEA100A2VEB ADEA125A2VEB...

Page 2: ...allation of the system and all activities described in the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANG...

Page 3: ...it User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product informa...

Page 4: ...CZECH REPUBLIC s r o U Nov Hospody 1 1155 301 00 Plze Skvr any Czech Republic A B C D E ADEA125A 7 83 4 27 13 50 0 35 62 3 3 User interface CAUTION NEVER touch the internal parts of the controller Do...

Page 5: ...sion instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of peop...

Page 6: ...be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fire Do NOT rinse the unit Do NOT operate the unit wi...

Page 7: ...tips and procedures for cleaning are provided in the installation operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position 7 6 Maintenance after a...

Page 8: ...lfunctions 8 1 1 Symptom The system does not operate The air conditioner does not start immediately after the ON OFF button on the user interface is pressed If the operation lamp lights the air condit...

Page 9: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Page 10: ......

Page 11: ......

Page 12: ...4P551388 1 2018 09 Copyright 2018 Daikin...

Reviews: