background image

6 Energy saving and optimum operation

User reference guide

5

ADEA35~125A2VEB
Split system air conditioners
4P551388-1 – 2018.09

AZQS71~125

Cooling

Heating

Indoor humidity

≤80%

(a)

For combination with 

R32 outdoor unit

, refer to the following table:

ARXM35~71

Cooling

Heating

Outdoor temperature

–10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor temperature

21~37°C DB

14~28°C WB

10~30°C DB

Indoor humidity

≤80%

(a)

AZAS71~125

Cooling

Heating

Outdoor temperature

–5~46°C DB

–15~21°C DB

–15~15.5°C WB

Indoor temperature

20~38°C DB

14~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

(a)

To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.

Setting temperature range of the user interface:

Cooling

Heating

17~32°C

16~31°C

5.2

Operation procedure

▪ Turn  on  the  power  at  least  6  hours  before  operating  the  unit  in

order  to  ensure  smoother  operation.  As  soon  as  the  power  is
turned on, the user interface display appears.

▪ If  there  was  a  power  failure  during  operation,  the  system

automatically  restarts  immediately  after  the  power  supply  is
recovered.

▪ The setting temperature range of the user interface is described in

chapter "Operation range".

▪ If  you  select  a  function  which  is  not  available,  the  message

 appears on the user interface.

▪ The  operation  procedure  depends  on  the  model  (heat  pump  or

cooling only). Contact your dealer to confirm which model you are
using.

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

6

Energy saving and optimum
operation

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays. Doing so may result in
a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

▪ Prevent  direct  sunlight  from  entering  a  room  during  cooling

operation by using curtains or blinds.

▪ Ventilate  often.  Extended  use  requires  special  attention  to

ventilation.

▪ Keep doors and windows closed. If the doors and windows remain

open,  air  will  flow  out  of  your  room  causing  a  decrease  in  the
cooling or heating effect.

▪ Be  careful  NOT  to  cool  or  heat  too  much.  To  save  energy,  keep

the temperature setting at a moderate level.

▪ NEVER place objects near the air inlet or the air outlet of the unit.

Doing  so  may  cause  a  reduced  heating/cooling  effect  or  stop
operation.

▪ Turn off the main power supply switch to the unit when the unit is

NOT  used  for  longer  periods  of  time.  If  the  main  power  supply
switch  is  on,  the  unit  consumes  electricity.  Before  restarting  the
unit,  turn  on  the  main  power  supply  switch  6  hours  before
operation to ensure smooth running.

▪ When the display shows 

 (time to clean the air filter), clean the

filters (see 

"7.4.2 To clean the air filter" on page 7

).

▪ Condensation  may  form  if  the  humidity  is  above  80%  or  if  the

drain outlet gets blocked.

▪ Adjust  the  room  temperature  properly  for  a  comfortable

environment.  Avoid  excessive  heating  or  cooling.  Notice  that  it
may  take  some  time  for  the  room  temperature  to  reach  the  set
temperature. Consider using the timer setting options.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

Refrigerant type: R410A

Summary of Contents for ADEA35A2VEB

Page 1: ...User reference guide Split system air conditioners English User reference guide Split system air conditioners ADEA35A2VEB ADEA50A2VEB ADEA60A2VEB ADEA71A2VEB ADEA100A2VEB ADEA125A2VEB...

Page 2: ...allation of the system and all activities described in the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANG...

Page 3: ...it User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product informa...

Page 4: ...CZECH REPUBLIC s r o U Nov Hospody 1 1155 301 00 Plze Skvr any Czech Republic A B C D E ADEA125A 7 83 4 27 13 50 0 35 62 3 3 User interface CAUTION NEVER touch the internal parts of the controller Do...

Page 5: ...sion instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of peop...

Page 6: ...be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fire Do NOT rinse the unit Do NOT operate the unit wi...

Page 7: ...tips and procedures for cleaning are provided in the installation operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position 7 6 Maintenance after a...

Page 8: ...lfunctions 8 1 1 Symptom The system does not operate The air conditioner does not start immediately after the ON OFF button on the user interface is pressed If the operation lamp lights the air condit...

Page 9: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Page 10: ......

Page 11: ......

Page 12: ...4P551388 1 2018 09 Copyright 2018 Daikin...

Reviews: