14. Re-attach all sensors and connectors to the appropriate 

terminals along the left side of the control board. Replace 
the control box cover in reverse order as described in 

Figure 16 on page 8

.

NOTICE

  Use a proper method of bundling and securing the wires and con-

nections so that they do not snag or pull while replacing the con-
trol box cover and control box.

15. Replace control box, performing step 4 in reverse order 

while referring to 

Figure 15 on page 8

.

16. Remove the ExtendAire primary discharge section from the 

unit, referring to 

Figure 10 on page 5 

assembly details.

17. Slide ExtendAire Boost Fan Assembly into 3' extension 

section, with power cord directed toward unit control box, 
while making sure to take care with the existing insulation 
The Boost Fan Assembly should be positioned midway 
inside the 3' extension section, (see 

Figure 22

).

18. Remove backing from one (1) zip-tie mount and adhere it 

approximately 10" away from where the power cord enters 
the boost fan (to the inside-back wall of the 3' extension 
section). Secure the cord at this point with a zip-tie (

Figure 

22

). Place the two (2) remaining zip-tie mounts close to 

the edge of the discharge opening on the unit. See Notice 
below.

NOTICE

  Be sure that the two zip-tie mounts along the unit discharge sec-

tion are not positioned too near or at the point where the primary 
discharge mounting brackets are to be positioned. The boost fan 
power cord will be routed over the top of the mounting brackets of 
the primary discharge section as shown in

 Figure 22

 detail.

19. If ExtendAire is installed as a right hand discharge, coil 

excess boost fan power cord away from discharge opening.

20. Remove the LUI touchpad from the unit control door 

opening.

21. If primary ExtendAire discharge section has a reach-

through style door, remove the discharge grille section by 
carefully straightening tabs on the underside of the grille. 
Refer to step 4 and 

Figure 9 on page 4

 to reference 

method for removing grille section,

 

otherwise skip to step 

24.

NOTICE

  Refer to step 4 and

 Figure 9 on page 4

 to reference method 

for removing grille section.

22. Remove current door and replace with door provided in kit.

23. Re-install grille section in ExtendAire primary section and 

bend tabs back into original position.

10. Feed the (green) ground wire from the boost fan motor 

harness through one of the three wiring grommets at the 
bottom section of the control box and attach it to the 
existing ground screw as shown in 

Figure 20

Note: for clarity, all wires not shown.

Figure 20: Attach ground wire at the existing ground screw 
located on the bottom of the control box

Ground wire routed 
through wiring grommet 
to ground screw

Ground screw

11. If the unit is provided with standby power, remove the wire 

connector from the L2-STBY terminal and attach it to the 
piggy-back terminal on the white wire of the boost fan 
motor harness, as shown in 

Figure 21

.

Figure 21: Attach existing L2-STBY wire to piggy-back 
terminal on the white wire from the boost fan motor wire 
harness

White wire with 
piggy-back connector 
attaches to L2-STBY

L2-STBY 
Terminal

Premium 

Control Board

If Standby power wire exists on L2-STNBY, 
attach to white wire piggy-back connector

12. Attach the white wire connector with the piggy-back to L2-

STBY terminal on the board.

13. If the unit does not have standby power, remove the 

protective plastic cap from terminal L2-STBY on the board 
and attach the white wire connector from the boost fan 
motor wire harness to the L2-STBY terminal. DO NOT cut 
jumpers JW1 or JW2.

Summary of Contents for 910116725

Page 1: ...ity in Each Package Part Number Primary Discharge Section1 1 910106134 Shelf Discharge Assembly Primary Discharge Section1 1 Shelf Discharge Assembly 3 Foot Extension Section 1 Shelf Discharge Assembly Shelf Discharge Section 1 910106137 Shelf Discharge Assembly Trim Piece 2 Shelf Discharge Assembly End Cap 2 Side Wall Outlet Assembly2 Primary Discharge Section1 1 Side Wall Outlet Assembly2 3 Foot...

Page 2: ...hillips head screw on top of the mounting bracket to secure the discharge section to the cabinet wall sleeve Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sleeve and that it is aligned squarely with the front edge of the cabinet wall sleeve CAUTION ExtendAire Optional Boost Fan Installation Procedure Models PDAE and PDHE Installation and maintenan...

Page 3: ... pad up and through the primary discharge section control door opening Check the communication cable for proper connection to the Touchpad and the control board Figure 5 Position and tighten screws on mounting brackets to secure primary discharge section to cabinet wall sleeve Locate Right and Left Mounting Bracket Primary Discharge Section Mounting Bracket Assembly Mounting Bracket Detail 4 Snap ...

Page 4: ...he underside of the touchpad control opening Unplug the touchpad com munication cable from the control board 3 Remove the two 2 screws located at each end of the cabinet wrap securing it to the wall sleeve Lift slightly and pull the cabinet wrap away from the unit chassis wall sleeve Figure 8 Figure 8 Remove two 2 screws securing the cabinet wrap to the wall sleeve lift slightly and pull away cabi...

Page 5: ...ord will pass through the primary discharge section and over the mounting brackets and not underneath Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sleeve and that it is aligned squarely with the front edge of the cabinet wall sleeve 8 Reinstall the touchpad controller by plugging in the communication cable into the receptacle in the control board...

Page 6: ...t wall sleeve Refer to the specific configuration for installation details Note Upon completion of the selected configuration refer to steps 2 3 and 4 on page 7 Configuration 1 Shelf Discharge Assembly Refer to Figure 13 a Butt end of one L shaped piece of 3 Extension Section against Primary Discharge Section Attach to wall with screws or nails b Snap second L shaped piece of 3 Extension Section i...

Page 7: ...illes to the right and inactive grilles to the left when facing unit 3 Cover joints with trim pieces 4 Make sure there is at least 35 sq in free area return air opening from adjoining room Undercut door or provide louver to provide return air Figure 14 Side Wall Outlet Assembly Details ExtendAire Capacity Selection Table 3 ExtendAire Capacity Selection1 Primary Primary Room Adjoining Room Approxim...

Page 8: ...nd Figure 8 on page 4 To remove the chassis remove screws at locations shown in Note After completing steps 2a or 2b and 3a or 3b continue the Boost Fan installation as follows Figure 15 Remove the two 2 screws holding control box to the chassis Remove two 2 screws holding control box assembly to chassis Control Box Assembly 4 Remove the two 2 screws holding the control box to the chassis as shown...

Page 9: ...Figure 19 and insert the end of the orange wire detached from the plug connector into the kit provided butt connector and crimp In the opposite end of the butt connector insert the orange wire attached to the plug connector and the orange wire from the kit provided fan motor wire harness and crimp Repeat for Purple wire using pink wire from the kit motor wire harness Figure 19 Make wire connection...

Page 10: ...20 Remove the LUI touchpad from the unit control door opening 21 If primary ExtendAire discharge section has a reach through style door remove the discharge grille section by carefully straightening tabs on the underside of the grille Refer to step 4 and Figure 9 on page 4 to reference method for removing grille section otherwise skip to step 24 NOTICE Refer to step 4 and Figure 9 on page 4 to ref...

Page 11: ... the unit to provide control to the boost fan Figure 23 29 Feed the LUI communication cable through the control door opening in the primary discharge section and plug into the COM terminal on the premium control board Also re connect the remaining connectors onto the appropriate terminals at the top of the premium control board Figure 22 Boost Fan assembly details Boost fan positioned midway insid...

Page 12: ...ld pursuant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Representative for warranty details Refer to Form 933 430285Y To find your local Daikin Representative go to www DaikinAP com Aftermarket Services To find your local parts office visit www DaikinAP com or call 800 37PARTS 800 377 2787 To find your local service office visit www Dai...

Reviews: