24. Reattach ExtendAire primary section to the unit. See step 

7 and refer to 

Figure 10 on page 5

 for installation  

instructions. Re-attach the 3' extension to the primary 
discharge section and through the adjoining room cutout.

25. Secure the boost fan power cord within the primary 

discharge section with the two remaining zip-ties.

NOTICE

  The boost fan power cord must run over the top of the primary 

discharge section mounting brackets, see 

Figure 22

 detail.

26. Reinstall unit chassis into wall sleeve, if removed. 

27. Route the boost fan power cord plug through the discharge 

air opening in the cabinet/wall sleeve. The plug should exit 
along the side of the control box where it will plug into the 
boost fan motor wire harness (See detail in 

Figure 22 and 

Figure 23

).

28. Connect the two Molex connectors inside the unit to 

provide control to the boost fan (

Figure 23

).

29. Feed the LUI communication cable through the control 

door opening in the primary discharge section and plug into 
the COM terminal on the premium control board. Also, 
re-connect the remaining connectors onto the appropriate 
terminals at the top of the premium control board.

Figure 22: Boost Fan assembly details

Boost fan positioned 
midway inside 
extension section

Boost fan power cord 
secured with two (2) zip 
ties in primary section

Trim piece

Removed right end 
and left end grilles

Boost fan power cord plug

Primary discharge air section

Detail

Zip-tie location (1) in 
3' extension section

Figure 23: Make plug connection of boost fan to fan motor

Boost Fan power cord 
connector into Fan 
Motor wire harness 
connector

30. Snap LUI touchpad control bezel into the opening of the 

control access door.

31. Return the front panel to the cabinet/wall sleeve and restore 

power to the unit.

Note:  Boost fan will run whenever indoor fan is operational, 

regardless of speed of indoor fan.

Summary of Contents for 910116725

Page 1: ...ity in Each Package Part Number Primary Discharge Section1 1 910106134 Shelf Discharge Assembly Primary Discharge Section1 1 Shelf Discharge Assembly 3 Foot Extension Section 1 Shelf Discharge Assembly Shelf Discharge Section 1 910106137 Shelf Discharge Assembly Trim Piece 2 Shelf Discharge Assembly End Cap 2 Side Wall Outlet Assembly2 Primary Discharge Section1 1 Side Wall Outlet Assembly2 3 Foot...

Page 2: ...hillips head screw on top of the mounting bracket to secure the discharge section to the cabinet wall sleeve Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sleeve and that it is aligned squarely with the front edge of the cabinet wall sleeve CAUTION ExtendAire Optional Boost Fan Installation Procedure Models PDAE and PDHE Installation and maintenan...

Page 3: ... pad up and through the primary discharge section control door opening Check the communication cable for proper connection to the Touchpad and the control board Figure 5 Position and tighten screws on mounting brackets to secure primary discharge section to cabinet wall sleeve Locate Right and Left Mounting Bracket Primary Discharge Section Mounting Bracket Assembly Mounting Bracket Detail 4 Snap ...

Page 4: ...he underside of the touchpad control opening Unplug the touchpad com munication cable from the control board 3 Remove the two 2 screws located at each end of the cabinet wrap securing it to the wall sleeve Lift slightly and pull the cabinet wrap away from the unit chassis wall sleeve Figure 8 Figure 8 Remove two 2 screws securing the cabinet wrap to the wall sleeve lift slightly and pull away cabi...

Page 5: ...ord will pass through the primary discharge section and over the mounting brackets and not underneath Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sleeve and that it is aligned squarely with the front edge of the cabinet wall sleeve 8 Reinstall the touchpad controller by plugging in the communication cable into the receptacle in the control board...

Page 6: ...t wall sleeve Refer to the specific configuration for installation details Note Upon completion of the selected configuration refer to steps 2 3 and 4 on page 7 Configuration 1 Shelf Discharge Assembly Refer to Figure 13 a Butt end of one L shaped piece of 3 Extension Section against Primary Discharge Section Attach to wall with screws or nails b Snap second L shaped piece of 3 Extension Section i...

Page 7: ...illes to the right and inactive grilles to the left when facing unit 3 Cover joints with trim pieces 4 Make sure there is at least 35 sq in free area return air opening from adjoining room Undercut door or provide louver to provide return air Figure 14 Side Wall Outlet Assembly Details ExtendAire Capacity Selection Table 3 ExtendAire Capacity Selection1 Primary Primary Room Adjoining Room Approxim...

Page 8: ...nd Figure 8 on page 4 To remove the chassis remove screws at locations shown in Note After completing steps 2a or 2b and 3a or 3b continue the Boost Fan installation as follows Figure 15 Remove the two 2 screws holding control box to the chassis Remove two 2 screws holding control box assembly to chassis Control Box Assembly 4 Remove the two 2 screws holding the control box to the chassis as shown...

Page 9: ...Figure 19 and insert the end of the orange wire detached from the plug connector into the kit provided butt connector and crimp In the opposite end of the butt connector insert the orange wire attached to the plug connector and the orange wire from the kit provided fan motor wire harness and crimp Repeat for Purple wire using pink wire from the kit motor wire harness Figure 19 Make wire connection...

Page 10: ...20 Remove the LUI touchpad from the unit control door opening 21 If primary ExtendAire discharge section has a reach through style door remove the discharge grille section by carefully straightening tabs on the underside of the grille Refer to step 4 and Figure 9 on page 4 to reference method for removing grille section otherwise skip to step 24 NOTICE Refer to step 4 and Figure 9 on page 4 to ref...

Page 11: ... the unit to provide control to the boost fan Figure 23 29 Feed the LUI communication cable through the control door opening in the primary discharge section and plug into the COM terminal on the premium control board Also re connect the remaining connectors onto the appropriate terminals at the top of the premium control board Figure 22 Boost Fan assembly details Boost fan positioned midway insid...

Page 12: ...ld pursuant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Representative for warranty details Refer to Form 933 430285Y To find your local Daikin Representative go to www DaikinAP com Aftermarket Services To find your local parts office visit www DaikinAP com or call 800 37PARTS 800 377 2787 To find your local service office visit www Dai...

Reviews: