![background image](http://html.mh-extra.com/html/daikin/4mxl36tvju/4mxl36tvju_service-manual-removal-procedure_501132024.webp)
Four Way Valve / Electronic Expansion Valve for Bypass Circuit
Si121858E
22
Removal Procedure
2
3
Remove the protection
bushing.
Disconnect the
compressor lead wires.
4
5
Remove the putty.
Heat up the 4 brazed
parts and remove the
four way valve.
The fusible plug melts at
70°C (158°F). Make sure to
cover the fusible plug not to
be heated up with protection
sheet.
2. Remove the electronic
expansion valve for
bypass circuit.
The fusible plug melts at
70°C (158°F). Make sure to
cover the fusible plug not to
be heated up with protection
sheet.
1
Heat up the 2 brazed
parts and remove the
electronic expansion
valve for bypass circuit.
Step
Procedure
Points
Protection bushing
U (red)
V (yellow)
W (blue)
(R25816)
Four way valve
Brazed part
Putty
(R25817)
Fusible plug
(R25818)
Electronic
expansion valve
for bypass circuit
Brazed part
(R25819)
Fusible plug
(R25820)