![background image](http://html.mh-extra.com/html/daikin/4mxl36tvju/4mxl36tvju_service-manual-removal-procedure_501132017.webp)
Si121858E
Thermistor ASSY / Electronic Expansion Valve Coil for Bypass Circuit / Four Way Valve Coil
Removal Procedure
15
8
9
10
Cut the 3 clamps.
(clamp A)
Pull out the 2 clamps.
(clamp B)
Detach the wires from
the hook and remove
the thermistor ASSY.
4. Remove the electronic
expansion valve coil for
bypass circuit.
1
Pull out the clamp and
remove the electronic
expansion valve coil for
bypass circuit.
5. Remove the four way
valve coil.
Insert a long screwdriver
from the hole near the
terminal blocks.
1
Remove the screw and
remove the four way
valve coil.
Step
Procedure
Points
Clamp B
Hook
Clamp A
(R25792)
Thermistor
ASSY
(R25793)
Clamp
Electronic expansion valve coil for bypass circuit
(R25794)
Four way valve coil
(R25795)
Hole