Indoor/Outdoor Unit 

Installation Drawings

For installation of the indoor units, refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)

 CAUTION

• Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the 

indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See “7 Refrigerant piping work” on page 9 for details.

• It is impossible to connect the indoor unit for one room only. 

Be sure to connect at least 2 rooms

.

Caulk 
pipe hole 
gap 
with putty. 

Cut thermal insulation 
pipe to an appropriate 
length and wrap it with 
tape, making sure that no 
gap is left in the insulation 
pipe’s cut line.

Wrap the insulation 
pipe with the finishing 
tape from bottom to top.

250mm from wall

Allow space for piping 
and electrical servicing.

If there is the danger of the unit falling 
or overturning, fix the unit with 
foundation bolts, or with wire or other 
means.

If the location does not have good 
drainage, place the unit on a level 
mounting base (or a plastic pedestal). 
Install the outdoor unit in a level 
position. Failure to do so may result in 
water leakage or accumulation.

Level mounting 
base (optional parts)

(Foot bolt-

hole centres)

600

Clamping material

Insulation tube

Service lid

Tape

Also insulate the connection on the outdoor unit.

Use tape or insulating material on all connections 
to prevent air from getting in between the copper 
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed 
above.

(Foot bolt-hole 

 centres)

353

Stop valve cover

Allow 300mm of 
work space below 
the ceiling surface.

unit: mm

Max. allowable refrigerant charge amount

3MXM40M

2.2kg

3(A)MXM52M

2.2kg

3MXM68M

2.4kg

4MXM68M

2.6kg

4MXM80M

3.0kg

5MXM90M

3.3kg

Refrigerant piping must be kept to 
a minimum.

3MXM40M

4.7m

2

3(A)MXM52M

4.7m

2

3MXM68M

5.5m

2

4MXM68M

6.5m

2

4MXM80M

8.6m

2

5MXM90M

10.4m

2

Minimum floor area for installation

The flare connection 
should be installed 
outdoors.

Refrigerant piping must 
be protected from 
physical damage. 
Install a plastic cover or 
equivalent.

Summary of Contents for 3MXM40M2V1B

Page 1: ...INSTALLATION MANUAL R32 Split Series Models 3MXM40M2V1B 3MXM52M2V1B 3AMXM52M2V1B 3MXM68M2V1B 4MXM68M2V1B 4MXM80M2V1B 5MXM90M2V1B Deutsch Fran ais Nederlands Espa ol Italiano Portugues T rk e...

Page 2: ...len D som positivt intygats av E Fastsatt modul F vilket ocks framg r av Certifikat G Riskkategori H Se ven n sta sida 12 som det fremkommer i A og gjennom positiv bed mmelse av B if lge Sertifikat C...

Page 3: ...urvele PS vastav k llastunud temperatuur M C Jahutusaine N Surve turvaseadme seadistus P bar Tootmisnumber ja tootmisaasta vaadake mudeli andmeplaati 21 PS K bar TS TSmin L C TSmax PS M C N P bar 22 M...

Page 4: ...strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting the wiring between the in...

Page 5: ...imals making contact with electrical parts can cause malfunctions smoke or fire Please instruct the customer to keep the area around the unit clean The temperature of refrigerant circuit will be high...

Page 6: ...y be heard even if they are more than 3m away depending on radio wave conditions 8 In coastal areas or other places with salty atmosphere of sulfate gas corrosion may shorten the life of the air condi...

Page 7: ...ning fix the unit with foundation bolts or with wire or other means If the location does not have good drainage place the unit on a level mounting base or a plastic pedestal Install the outdoor unit i...

Page 8: ...allation ground so that the unit will not cause any operating vibration or noise after installed In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts Pre...

Page 9: ...gth per room is 3m Outdoor unit capacity class 3MXM40M 3MXM52M 3AMXM52M 3MXM68M 4MXM68M 4MXM80M 5MXM90M Piping to each indoor unit 25m max 25m max 25m max 25m max 25m max 25m max Total length of pipin...

Page 10: ...ials and installation shall comply with the applicable legislation In Europe the EN378 is the applicable standard that shall be used Ensure that the field piping and connections are not subjected to s...

Page 11: ...pe joints should be tightened with a torque wrench to the specified tightening torque 1 Connect projection side of charging hose which comes from gauge manifold to gas stop valve s service port 2 Full...

Page 12: ...piping for all rooms 30m 3 5 6 2 1 4 Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 the additional refrigerant amount charged in the field and 1 2 the total refri...

Page 13: ...made WARNING Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous in...

Page 14: ...readed connection port of the outdoor unit where the flare nut comes in Use an appropriate wrench to avoid damaging the connection thread by overtightening the flare nut Flare nut tightening torque Fl...

Page 15: ...Service lid 2 screws 3 Remove the service PC board switch cover 1 screw 4 Switch SW5 and SW6 to off 5 Turn the operation mode switch SW2 to COOL 6 Screw the service PC board switch cover back on 1 sc...

Page 16: ...onnect the connection wires between the indoor and outdoor units so that the terminal numbers match Tighten the terminal screws securely We recommend a flathead screwdriver be used to tighten the scre...

Page 17: ...er supply is turned off The selective connector for standby electricity saving is required if an indoor unit other than the above applicable one is connected Good Round crimp style terminal Flat washe...

Page 18: ...ter standby mode according to the operation mode of the set indoor unit 1 2 Priority during high power operation If the indoor unit which is set for priority room setting is operating at high power th...

Page 19: ...However if Night Quiet Mode is running cooling capacity will be saved Setting procedure Turn the Night Quiet Mode switch SW6 1 to on HEAT Mode Lock SW5 1 Use the HEAT Mode Lock switch SW5 1 in the ON...

Page 20: ...ms LED 4 and 5 is not displayed and for four rooms LED 5 is not displayed 2 If the outside air temperature is 5 C or less the wiring error check function will not operate 3 After wiring error check op...

Page 21: ...e the unit correctly particularly cleaning of the air filters operation procedures and temperature adjustment Even when the air conditioner is not operating it consumes some electric power If the cust...

Page 22: ...g Cooling Refnet header Applicable models 3MXM52M2V1B 3MXM40M2V1B 3AMXM52M2V1B S1PH S2PH High pressure switch Manual reset Automatic reset Outdoor Unit Heat exchanger thermistor Outdoor air temperatur...

Page 23: ...lve 9 5CuT 9 5CuT 6 4CuT 12 7CuT 7 9CuT MVD 6 4CuT RoomD 6 4CuT D 12 7CuT 12 7CuT Room Outdoor Unit Heat exchanger thermistor Outdoor air temperature thermistor 15 9CuT 7 9CuT 7 9CuT 7 9CuT 7 9CuT 12...

Page 24: ...B C Electronic expansion valve 6 4CuT 6 4CuT 6 4CuT Filter Room Room Room Field piping Liquid Gas A B C 6 4CuT 6 4CuT 6 4CuT Room Room Room 9 5CuT Liquid stop valve 9 5CuT 9 5CuT Muffler with filter...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...3P417620 1C 2016 01 Copyright 2015 Daikin...

Reviews: