Precautions for Selecting the Location

1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbours of 

the user.

3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit wire at least 3m away from television and radio sets. This is to prevent interference to 

images and sounds. (Noises may be heard even if they are more than 3m away depending on radio wave conditions.)

8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since water will flow from the drain of the outdoor unit, do not place under the unit anything which must be kept away from mois-

ture.

NOTE

Cannot be installed hanging from ceiling or stacked.

 CAUTION

When operating the air conditioner in a low outdoor ambient 
temperature, be sure to follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its suction 

side facing the wall.

• Never install the outdoor unit at a site where the suction side may be 

exposed directly to wind.

• To prevent exposure to wind, it is recommended to install a baffle 

plate on the air discharge side of the outdoor unit.

• In heavy snowfall areas, select an installation site where the snow 

will not affect the unit.

● Construct a large canopy
● Construct a pedestal

Install the unit high enough off the 
ground to prevent burying in snow.

Summary of Contents for 3MXM40M2V1B

Page 1: ...INSTALLATION MANUAL R32 Split Series Models 3MXM40M2V1B 3MXM52M2V1B 3AMXM52M2V1B 3MXM68M2V1B 4MXM68M2V1B 4MXM80M2V1B 5MXM90M2V1B Deutsch Fran ais Nederlands Espa ol Italiano Portugues T rk e...

Page 2: ...len D som positivt intygats av E Fastsatt modul F vilket ocks framg r av Certifikat G Riskkategori H Se ven n sta sida 12 som det fremkommer i A og gjennom positiv bed mmelse av B if lge Sertifikat C...

Page 3: ...urvele PS vastav k llastunud temperatuur M C Jahutusaine N Surve turvaseadme seadistus P bar Tootmisnumber ja tootmisaasta vaadake mudeli andmeplaati 21 PS K bar TS TSmin L C TSmax PS M C N P bar 22 M...

Page 4: ...strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting the wiring between the in...

Page 5: ...imals making contact with electrical parts can cause malfunctions smoke or fire Please instruct the customer to keep the area around the unit clean The temperature of refrigerant circuit will be high...

Page 6: ...y be heard even if they are more than 3m away depending on radio wave conditions 8 In coastal areas or other places with salty atmosphere of sulfate gas corrosion may shorten the life of the air condi...

Page 7: ...ning fix the unit with foundation bolts or with wire or other means If the location does not have good drainage place the unit on a level mounting base or a plastic pedestal Install the outdoor unit i...

Page 8: ...allation ground so that the unit will not cause any operating vibration or noise after installed In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts Pre...

Page 9: ...gth per room is 3m Outdoor unit capacity class 3MXM40M 3MXM52M 3AMXM52M 3MXM68M 4MXM68M 4MXM80M 5MXM90M Piping to each indoor unit 25m max 25m max 25m max 25m max 25m max 25m max Total length of pipin...

Page 10: ...ials and installation shall comply with the applicable legislation In Europe the EN378 is the applicable standard that shall be used Ensure that the field piping and connections are not subjected to s...

Page 11: ...pe joints should be tightened with a torque wrench to the specified tightening torque 1 Connect projection side of charging hose which comes from gauge manifold to gas stop valve s service port 2 Full...

Page 12: ...piping for all rooms 30m 3 5 6 2 1 4 Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 the additional refrigerant amount charged in the field and 1 2 the total refri...

Page 13: ...made WARNING Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous in...

Page 14: ...readed connection port of the outdoor unit where the flare nut comes in Use an appropriate wrench to avoid damaging the connection thread by overtightening the flare nut Flare nut tightening torque Fl...

Page 15: ...Service lid 2 screws 3 Remove the service PC board switch cover 1 screw 4 Switch SW5 and SW6 to off 5 Turn the operation mode switch SW2 to COOL 6 Screw the service PC board switch cover back on 1 sc...

Page 16: ...onnect the connection wires between the indoor and outdoor units so that the terminal numbers match Tighten the terminal screws securely We recommend a flathead screwdriver be used to tighten the scre...

Page 17: ...er supply is turned off The selective connector for standby electricity saving is required if an indoor unit other than the above applicable one is connected Good Round crimp style terminal Flat washe...

Page 18: ...ter standby mode according to the operation mode of the set indoor unit 1 2 Priority during high power operation If the indoor unit which is set for priority room setting is operating at high power th...

Page 19: ...However if Night Quiet Mode is running cooling capacity will be saved Setting procedure Turn the Night Quiet Mode switch SW6 1 to on HEAT Mode Lock SW5 1 Use the HEAT Mode Lock switch SW5 1 in the ON...

Page 20: ...ms LED 4 and 5 is not displayed and for four rooms LED 5 is not displayed 2 If the outside air temperature is 5 C or less the wiring error check function will not operate 3 After wiring error check op...

Page 21: ...e the unit correctly particularly cleaning of the air filters operation procedures and temperature adjustment Even when the air conditioner is not operating it consumes some electric power If the cust...

Page 22: ...g Cooling Refnet header Applicable models 3MXM52M2V1B 3MXM40M2V1B 3AMXM52M2V1B S1PH S2PH High pressure switch Manual reset Automatic reset Outdoor Unit Heat exchanger thermistor Outdoor air temperatur...

Page 23: ...lve 9 5CuT 9 5CuT 6 4CuT 12 7CuT 7 9CuT MVD 6 4CuT RoomD 6 4CuT D 12 7CuT 12 7CuT Room Outdoor Unit Heat exchanger thermistor Outdoor air temperature thermistor 15 9CuT 7 9CuT 7 9CuT 7 9CuT 7 9CuT 12...

Page 24: ...B C Electronic expansion valve 6 4CuT 6 4CuT 6 4CuT Filter Room Room Room Field piping Liquid Gas A B C 6 4CuT 6 4CuT 6 4CuT Room Room Room 9 5CuT Liquid stop valve 9 5CuT 9 5CuT Muffler with filter...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...3P417620 1C 2016 01 Copyright 2015 Daikin...

Reviews: