Outdoor Unit
Si121177
34
Removal Procedure
1.8
Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Disconnect the 3 lead
wires of the
compressor.
3
Remove the overload
protector.
4
Remove the bushing.
5
Remove the 3 nuts.
Terminal
cover
(R13714)
Overload protector
(R15746)
Lead wires
Red (U)
Yellow (V)
Blue (W)
(R12436)
Bushing
(R13716)