Si121177
Outdoor Unit
Removal Procedure
17
1.3
Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S70].
[S70]: fan motor
2
Release the fan motor
lead wire from the 5
hooks.
+
: When reassembling, do not
use these 2 hooks.
3
Disconnect the
connectors for the
electronic expansion
valve coils [S20], [S21],
[S22].
Pull out the clamp.
[S20] (white): room A
[S21] (red) : room B
[S22] (blue) : room C
When reassembling, insert
the clamps into the small
holes as below.
[S70]
(R13662)
(R13663)
Fan motor
lead wire
+
[S20] [S21]
[S22]
(R15741)
Clamp
(R13762)
Electronic expansion
valve coils
Gas pipe thermistors
Thermistor
ASSY
Overload protector
and high pressure