![background image](http://html.mh-extra.com/html/daikin/3mks50e2v1b/3mks50e2v1b_technical-data-manual_501113007.webp)
• Outdoor Units • R-410A • MKS-E2V1B_E7V3B
1
2
• Split Sky Air • Outdoor Units
7
2
Specifications
Standard
Accessories
Item
Installation manual
Quantity
1pc
Item
Drain plug
Drain plug
Quantity
1pc
1pc
Item
Reducer assembly
Reducer assembly
Quantity
1set
1set
Notes
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature :
35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-2 ELECTRICAL SPECIFICATIONS
3MKS50E2V1B
4MKS58E2V1B
5MKS90E7V3B
Power Supply
Name
V1
V1
V3
Phase
1
1
1
Frequency
Hz
50
50
50
Voltage
V
220-240
220-240
220-240
Voltage range
Minimum
V
-10%
Maximum
V
+10%
Current
Starting current (cooling/heating) A
5.3
6.7
11.4
Wiring
connections
For Power
Supply
Quantity
3
3
4
For connection
with indoor
Quantity
4
4
5
Power Supply Intake
Outdoor unit only
2-1 TECHNICAL SPECIFICATIONS
3MKS50E2V1B
4MKS58E2V1B
5MKS90E7V3B