• Outdoor Units • R-410A • MKS-E2V1B_E7V3B
1
6
• Split Sky Air • Outdoor Units
117
6
Dimensional drawing & centre of gravity
6 - 1
Dimensional drawing
3D051792
3MKS50E
A
Liquid
J
6.4
95
Gas
J
9.5
85
unit (mm)
2-cuts for anchor bolts
Drain outlet
(I.D.
J
15.9 hose for connection)
Interconnecting piping and
wiring inlet
4-Earth terminal
Name plate
<room B>
Gas pipe
(
J
9.5 single union)
Liquid pipe
(
J
6.4 single union)
<room C>
Gas pipe
(
J
9.5 single union)
Liquid pipe
(
J
6.4 single union)
(M8 or M10)
Minimum space for air passage
Wall height on air outlet side = less than 1200
Outdoor air thermistor
Liquid stop valve
Service port
Gas stop valve
4-Terminal strip
2-
J
12 Hole
(M8 or M10)
DIMENSIONS A
H
%
1200
350
H > 1200
600
Installation space for discharge side (mm)
300 or more
<room A>
Gas pipe
(
J
9.5 single union)
Liquid pipe
(
J
6.4 single union)
3D051793
4MKS58E
A
Liquid
J
6.4
95
Gas
J
9.5
85
J
12.7
76
unit (mm)
2-cuts for anchor bolts
Drain outlet
(I.D.
J
15.9 hose for connection)
Interconnecting piping and
wiring inlet
5-Earth terminal
Name plate
<room C>
Gas pipe
(
J
12.7 single union)
Liquid pipe
(
J
6.4 single union)
<room D>
Gas pipe
(
J
12.7 single union)
Liquid pipe
(
J
6.4 single union)
(M8 or M10)
Minimum space for air passage
Wall height on air outlet side = less than 1200
Outdoor air thermistor
Liquid stop valve
Service port
Gas stop valve
5-Terminal strip
2-
J
12 Hole
(M8 or M10)
DIMENSIONS A
H
%
1200
350
H > 1200
600
Installation space for discharge side (mm)
300 or more
<room A>
Gas pipe
(
J
9.5 single union)
Liquid pipe
(
J
6.4 single union)
<room B>
Gas pipe
(
J
9.5 single union)
Liquid pipe
(
J
6.4 single union)