![Daikin 2MXS18NMVJU Service Manual Download Page 34](http://html.mh-extra.com/html/daikin/2mxs18nmvju/2mxs18nmvju_service-manual_501098034.webp)
Indoor Unit
SiUS121630EA
22
Printed Circuit Board Connector Wiring Diagram
Display/Signal
Receiver PCB
(A2P)
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
INTELLIGENT
EYE Sensor PCB
(A3P)
1) S51
Connector for control PCB (A1P)
2) S52
Connector for room temperature thermistor
3) S1W
Indoor unit
ON/OFF
button
4) H1P
LED for operation (multi-color)
5) H2P
LED for INTELLIGENT EYE (green)
6) JA
Address setting jumper
∗
Refer to page 216 for details.
S52
S51
S1W
JA
H2P
H1P
3P357402-2
1) S36
Connector for control PCB (A1P)
S36