![background image](http://html.mh-extra.com/html/daikin/2mx18axvju/2mx18axvju_service-manual_501078064.webp)
DAMA-SM-21-003
Troubleshooting
Service Diagnosis
59
Reference
Note
4.5 Thermistor or Related Abnormality (Indoor Unit)
Error Code
C4
Description
Indoor Heat Exchange Thermistor Short/Open.
Method of Error
Detection
The temperature detected by the thermistors determine thermistor errors.
Error Decision
Conditions
The resistance of the thermistor is out of range (0
Ω
or
∞
Ω
)
Supposed
Causes
Disconnection of connector
Defective thermistor(s)
Defective indoor unit PCB
Troubleshooting
C4
: Indoor heat exchanger thermistor
Check No.01
Refer to P.85
When replacing the defective thermistor(s), replace the thermistor as ASSY.
YES
NO
Check No. 01
Check the thermistor resistance
value.
YES
NO
Correct the connection.
Replace the defective
thermistor.
Replace the indoor unit PCB
(control PCB).
Normal ?
Normal ?
Check the connection of
connectors.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
DAMA-SM-21-003 -Inverter Multi Split-CTX Series.book Page 59 Wednesday, September 1, 2021 5:44 PM
Summary of Contents for 2MX18AXVJU
Page 2: ......