Main Functions
DAMA-SM-21-003
30
Functions and Control
Note
Note
Note
1.11 Other Functions
1.11.1 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.11.2 Indoor Unit ON/OFF Switch
Indoor unit
ON/OFF
switch is provided on the display of the unit.
Press
ON/OFF
switch once to start operation. Press once again to stop it.
ON/OFF
switch is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
Forced Cooling Operation
Forced cooling operation can be started by pressing
ON/OFF
switch for 5 ~ 9 seconds while the
unit is not operating.
Refer to page 94 for details.
Forced cooling operation will not be started if the
ON/OFF
switch is pressed for 10 seconds or
more.
1.11.3 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the operation restarts
automatically in the same conditions as before when the power supply is restored to the
conditions prior to the power failure.
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
1.11.4 Hot-start function
In order to prevent the cold air blast that normally comes when heating is started, the
temperature of the heat exchanger of the indoor is detected, and either the airflow is stopped or
is made very weak thereby carrying out comfortable heating of the room.
*
The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat gets turned ON.
Operation mode
Temperature setting
Airflow rate
CTX
AUTO
25°C (77°F)
Automatic
ON/OFF
switch
DAMA-SM-21-003 -Inverter Multi Split-CTX Series.book Page 30 Wednesday, September 1, 2021 5:44 PM