![background image](http://html1.mh-extra.com/html/daikin/2amk40fv1b/2amk40fv1b_service-manual-removal-procedure_3382536008.webp)
Removal of Electrical Box
Si12-891
6
Removal Procedure
7
Disconnect the
connectors [S20],
[S21], [S80].
The cooling only models do
not have the harness for
[S80].
[S20]: outdoor electronic
expansion valve coil for
room A (white)
[S21]: outdoor electronic
expansion valve coil for
room B (red)
[S80]: four way valve coil
8
Pull out the clamp from
the electrical box.
The clamp is push-mount
type.
9
Disconnect the relay
connector for the
compressor.
10
Disconnect the 2
connectors for the
reactor.
Step
Procedure
Points
[S20]
[S21]
[S80]
(R12532)
(R7583)
(R12533)
(R12534)