Si002155E
Compressor
Removal Procedure
25
2
Remove the putties as
necessary.
3
Press down on the
central protrusion (A) to
unfasten the 2 hooks,
and then remove the
overload protector.
When reassembling, make
sure that the 2 hooks are
securely fastened.
When replacing the
compressor, make sure to
replace the radiation sheet
on the back of the overload
protector.
4
5
6
7
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts of
the compressor.
Lift up the compressor
and remove it.
Step
Procedure
Points
(R26218)
Hook
A
(R26223)
(R26053)
Radiation sheet
Compressor
Brazed part of the
discharge side pipe
Brazed part of the
suction side pipe
Nut
(R26224)