![Daikin 18000 Btu Service Manual Download Page 25](http://html1.mh-extra.com/html/daikin/18000-btu/18000-btu_service-manual_502253025.webp)
Si002155E
Electronic Expansion Valve / Four Way Valve
Removal Procedure
23
3. Remove the four way
valve.
1
Remove the screw, and
then the four way valve
coil.
2
Heat up the 4 brazed
parts and remove the
four way valve.
Step
Procedure
Points
Four way valve coil
(R26221)
Four way valve
Brazed part
Brazed part
(R26222)