![Daikin 18000 Btu Service Manual Download Page 16](http://html1.mh-extra.com/html/daikin/18000-btu/18000-btu_service-manual_502253016.webp)
PCBs / Thermistor ASSY
Si002155E
14
Removal Procedure
5
Unfasten the 4
projections and remove
the service monitor
PCB.
2. Remove the main PCB.
1
Remove the earth/
ground screw.
2
3
Pull out the snap band.
Remove the 2 screws
of the terminal
mounting plate.
When finished the withstand
voltage test, make sure that
the harness is inside the
right side panel.
Step
Procedure
Points
Projection
Service monitor PCB
Projection
(R26198)
(R26199)
Earth/ground screw
Front view
Right view
Snap band
Withstand voltage harness
(R26200)