SMLC-213-154
2
Disposal
Please dispose this product as industrial waste (non-combustible).
Mercury parts and a nickel-cadmium battery are not used for this product.
Warranty period.
The warranty period of the product is one year after the date of delivery.
Operation
Be careful with the following cautions during use.
Use the input within the rated range. Be careful since negligence of this caution may cause troubles of the unit.
There is a function to hold the maximum value and the minimum value with a measurement factor in this product.
The blackout this value will not be cleared by a power supply reset. However, the minimum value may be updated in
case input is not applied to a power up. Therefore the maximum value and the minimum value need to be reset of DI
after a startup, or switch operation.
For this reason, in order to recover previous minimum value, please apply input within 1 second after switching on
a power supply.
The maximum value, a minimum value measurement factor
Measurement factor
Maximum value measurement Minimum value measurement
3-phase voltage,Zero-phase voltage,Frequency
○
○
Be careful not to touch any terminal when power is applied to the unit.
Don
’
t disassemble or modify this unit without any previous permission of our company, otherwise
the warranty does not apply to the unit any more. Also, modifications may cause troubles, a
fire, or other accidents. For specifications change, etc., please contact us.
Setting
This unit requires setting and confirmation of the measuring range, etc. before use.
Wrong setting, if any, causes malfunction of the unit. If setting should be wrong, neither measurement nor output
becomes correct. Carefully read the instruction manual before setting the unit.
Default settings
The case of shipment of this product, it is the following default setting. Please set according to a use condition.
№
Setting item
Phase voltage input
Line voltage input
Vo 190V
Vo 110V
Vo 190V
Vo 110V
1 Display combination
Pattern
Pattern 1
Pattern 1
Main monitor
Maximum zero-phase voltage Maximum zero-phase voltage
Sub-monitor (Left)
V(RS)
V(RS)
Sub-monitor (Center)
V(ST)
V(ST)
Sub-monitor (Right)
V(TR)
V(TR)
Bar graph
Maximum zero-phase voltage
+ Zero-phase voltage
Maximum zero-phase voltage
+ Zero-phase voltage
2
Alarm output setting
(
1
)
Alarm 1 factor
Zero-phase voltage
Zero-phase voltage
Alarm 1 reset form
AUTO <自動復帰>
AUTO <自動復帰>
Alarm 1 test <テスト>
-
-
Alarm 2 factor
OFF
OFF
Alarm 2 reset form
AUTO <自動復帰>
AUTO <自動復帰>
Alarm 2 test <テスト>
-
-
3
3-phase voltage
detection setting
Voltage upper limit
OFF
OFF
Voltage lower limit
OFF
OFF
Line voltage Time interval
0 second <秒>
0 second <秒>
4
Zero-phase voltage
detection setting
Zero-phase voltage upper limit 5280V ( /152V) 5280V ( /88V) 5280V ( /152V) 5280V ( /88V)
Response time
0.1 second <秒>
0.1 second <秒>
Ground fault phase detection
display automatic change
OFF
OFF
5 Backlight
Action
AUTO
AUTO
Brightness
3(Middle)
3(Middle)
6 Measurement range
Voltage range
9000V (6600V/110V)
9000V (6600V/110V)
Zero-phase voltage scale
×1/√
3
non display
×1/√
3
non display
Frequency range
45.0 to 65.0Hz
45.0 to 65.0Hz