background image

SDLC-207-104 

 

 
 
   ● Relay contact status 

Status 

4 contact outputs:Each 1a contact 

4 contact outputs:Each 1b contact 

Auxiliary supply OFF 
or relay 
non-excitation 

Terminal №

AL4

AL3

C2

10

9

11

AL2

AL1

C1

2

1

3

 

Terminal №

AL4

AL3

C2

10

9

11

AL2

AL1

C1

2

1

3

 

Relay excitation 

Terminal №

AL4

AL3

C2

10

9

11

AL2

AL1

C1

2

1

3

 

Terminal №

AL4

AL3

C2

10

9

11

AL2

AL1

C1

2

1

3

 

 

Status 

3 contact outputs:Each 1a contact 

3 contact outputs:Each 1b contact 

Auxiliary supply OFF 
or relay 
non-excitation 

Terminal №

AL3

10

9

11

AL1

AL2

2

1

3

 

Terminal №

AL3

10

9

11

AL1

AL2

2

1

3

 

Relay excitation 

Terminal №

AL3

10

9

11

AL1

AL2

2

1

3

Terminal №

AL3

10

9

11

AL1

AL2

2

1

3

 

Status 

2 contact outputs:Each 1c contact  

 

Auxiliary supply OFF or 
relay non-excitation 

Terminal №

AL2

10

9

11

2

1

3

c2

a2

b2

AL1

c1

a1

b1

 

 

Relay excitation 

Terminal №

AL2

10

9

11

2

1

3

c2

a2

b2

AL1

c1

a1

b1

 

 

 

Summary of Contents for SDLC-105A

Page 1: ...SDLC 207 104 INSTRUCTION MANUAL LCD ALARM SETTER SDLC 105A...

Page 2: ...epting wiring to terminal in order to prevent heat generation ignition Do not get this product near the inflammables combustible chemicals gas to prevent fire Connect specified power supply Connecting...

Page 3: ...ension drawing 10 3 3 Connection 11 3 4 Cautions on mounting 11 3 5 LCD viewing angle 12 4 Operation method 4 1 The name and function of each part 12 4 2 Each display mode and operation 13 4 3 Measure...

Page 4: ...e power failure guarantee of the set value Sufficient derating of uses parts and reduction of inside generation of heat improves reliability The back light is turned on at the case of key operation 30...

Page 5: ...s maximum of each It is monitor lamp turn on the light at the case of relay excitation It is blinking among delay time at the case of the prealarm setting ON Relay and monitor lamp operation At the au...

Page 6: ...l AL4 AL3 C2 10 9 11 AL2 AL1 C1 2 1 3 Status 3 contact outputs Each 1a contact 3 contact outputs Each 1b contact Auxiliary supply OFF or relay non excitation Terminal AL3 10 9 11 AL1 AL2 2 1 3 Termina...

Page 7: ...n in shortage input detection Output mode Excitation L Operation value setting Relay action ON OFF Input Contact delay setting time Contact delay setting time Contact delay setting time Dead band Sett...

Page 8: ...m function constitutes OFF Relay action and pre alarm in over input detection Output mode setting Excitation H Pre alarm setting ON Operation value setting Relay action ON OFF Dead band Setting value...

Page 9: ...y time CD C D 3 0 0 to 180s 19 AL4 Output mode ALMD4 Low High H operation Low L operation OFF With no operation 20 Operation value COMP4 20 0 It sets in the measurement display range of 25 to 125 and...

Page 10: ...electric circuit and case AC2000V 50 60Hz 1 minute There must not be malfunction Between input output terminals and auxiliary supply terminals Between input terminals and output terminals Between AL1...

Page 11: ...the state of a hot line please use UR 1 for a socket connecting converting into a voltage signal UR 1 resistance designation Option Resistance in input signal Input Resistance DC0 1mA DC0 10mA DC0 16m...

Page 12: ...mm width DIN rail mounting and screw mounting In screw mounting please mount with M4 screw However the screw is not attached And please give the mounting torque of a screw as 1 08 to 1 47N m 11 to 15k...

Page 13: ...ation Key switch The mode to display is changed Set value check The update of data is performed The shift of set value is performed Monitor lamp AL1 to AL4 The turn on a light by relay excitation If a...

Page 14: ...ange in set value change mode at the case of combination error occurrence Contents of error Measures ERROR 0 Scaling combination error In order that it may become MAX MIN it sets up again ERROR 1 COMP...

Page 15: ...UP UP UP UP SHIFT Measurement value display U N I T M I N 0 0 0 0 M A X 1 0 0 0 C B I A S 0 0 0 0 C S P A N 0 0 0 0 S D 0 0 0 s A V E MODE SHIFT C D 1 0 0 0 s A L M D 1 H i g h D B 1 0 3 0 E X M D 1...

Page 16: ...2 O N C D 2 0 0 0 s A L M D 3 L o w C O M P 3 0 3 0 0 D B 3 0 3 0 E X M D 3 O N C D 3 0 0 0 s A L M D 4 L o w C O M P 4 0 2 0 0 D B 4 0 3 0 E X M D 4 O N C D 4 0 0 0 s UP P R E A L O F F It is made t...

Page 17: ...umber of the top digit becomes minus after 0 to 9 Note 12 The number of digits other than the top digit becomes decimal point after 0 to 9 However if decimal point is in other digits decimal point doe...

Page 18: ...e This voltage goes into an amplifier 2 The input is converted into the suitable voltage range in an amplifier This voltage constitutes an input of an A D converter 3 The data converted into digital o...

Page 19: ...careful of the next item 1 It is checked whether a body and socket combination are normal is a lock a totality 2 It checks for the slack of wiring and the slack of a captive screw 3 It will remove if...

Page 20: ...m setter Display error Small error Secular change of input measurement Display is proofread again Reference of instruction manual 7 2 section Set value cannot be changed The error of the setting metho...

Page 21: ...setting change mode and use the seal accessory in combination Unit symbol sheet Accessory If there is no unit symbol you want to use in the above sheet by specifying the unit symbol at the time of or...

Page 22: ...13 Hitotsuya 1 chome Adachi ku Tokyo 121 8639 JAPAN TEL 81 3 3885 2411 Fax 81 3 3858 3966 Kyoto Office 1 19 Ichinobe Nishikawahara Jyoyou shi Kyoto 610 0114 JAPAN TEL 81 774 55 1391 Fax 81 774 54 1353...

Reviews: