background image

Q-222-039 

 

 
 

 

Countermeasures against troubles 

If trouble occurs within the warranty period, DAIICHI ELECTRONICS will repairs this product. 

 

 

Disposal 

Please dispose this product as industrial waste (non-combustible). 
Mercury parts and a nickel-cadmium battery are not used for this product. 

 

 

Warranty period 

The warranty period of the product is one year after the date of delivery. 

 

 

Warranty scope 

In the case that a defect is found in our product during the warranty period due to our responsibility, 
we will replace the defective part and repair. 
However, we will not be liable if the faults or defects are under any of the following items. 

 When the faults or defects are resulted from the modification or repair carried out by any other entity 

than our company. 

 Failure caused by violating various conditions regarding use, storage, etc. specified by the supplier. 

 When the faults or defects are caused by a reason not belongs to purchased or delivered products. 

 Damage or malfunction due to relocation or other transportation, movement or dropping. 

 In case that the faults or defects are resulted from force majeure such as fire or abnormal voltage  

and natural calamity or disaster. 

Our company shall not be liable for compensation of damages caused by any reason which is not our 
responsibility, loss opportunity, loss profits incurred to the user, special damages and consequential 
damages whether foreseeable or not, or damages not relating to our products. 

 

 

Replacement cycle of the product  

We recommend updating the product for 10 years as a rough standard. 

 

 

Change of instruction manual written contents 

This instruction manual changes written contents without a notice by product improvement etc. 

 

Summary of Contents for PTT2-92A-12

Page 1: ...Q 222 039 INSTRUCTION MANUAL V I PHASE ANGLE TRANSDUCER PTT2 92A 12 PTT2 92A 33 PTT2 92A 34 MODEL B...

Page 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Page 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Page 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 7 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Page 5: ...92A 12 M4 screw 4 piece set 1 M4 screw 5 piece set 1 PTT2 92A 33 M4 screw 4 piece set 1 M4 screw 7 piece set 1 PTT2 92A 34 M4 screw 4 piece set 2 M4 screw 5 piece set 1 4 Mounting method Please insta...

Page 6: ...e this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from th...

Page 7: ...ightening torque 1 0 to 1 3 N m PTT2 92A 12 PTT2 92A 33 PTT2 92A 34 Connection diagram PTT2 92A 12 PTT2 92A 33 PTT2 92A 34 AUX SUPPLY L P1 K U 2 1 V 1S E A B OUTPUT P2 AUX SUPPLY P1 A B OUTPUT P2 AUX...

Page 8: ...uxiliary power supply and voltage input are applied is the output equivalent to the input 0 7 Specification 7 1 Rating Item Specification Input Phase angle LEAD 60 to LAG 60 Please specify LEAD 90 to...

Page 9: ...g inverter output Cycle control PWM inverter SCR phase angle control Adjustment range The output adjustment range is BIAS 5 of the output span MAX 5 of the output span Use only when adjustment is requ...

Page 10: ...es 1 second of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated curren...

Page 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Page 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Page 13: ...rm use please adjust in the next way Remove the terminal cover and VR cap before adjustment and attach the VR cap and terminal cover after adjustment 1 For the output load connect an actual load withi...

Page 14: ...r less Z Other V I Phase Angle Transducer Three phase four wire Type Specification code PTT2 92A 34 Model Input Rated voltage Rated current Output Output load range Auxiliary supply B Model B 1 LEAD 6...