Summary of Contents for FWVTT2-92A-33

Page 1: ...Q 222 031 INSTRUCTION MANUAL POWER FLOW THREE PHASE REACTIVE POWER TRANSDUCER FWVTT2 92A 33...

Page 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Page 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Page 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 8 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Page 5: ...with a width of 35mm The terminal cover is standard equipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 5 piece set 1 M4 screw 7 piece set 1 4 Mo...

Page 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Page 7: ...orque 1 0 to 1 3 N m Connection diagram AUX SUPPLY P1 1S 3 1 2 S1 1L 3S S2 P2 OUTPUT A B 3L P3 E LOAD Grounding is class D grounding grounding resistance 100 or less If there is a power line that caus...

Page 8: ...be burdened Especially for voltage output products do not short circuit the output This product will not be damaged even if the output terminal is left open in the current output specifications Howev...

Page 9: ...ess 5 3ms DC48V 3 1A or less 5 3ms Note Refer to the specification code for other ratings 7 2 Performance Item Specification Class index 0 5 Response time 1 second or less Ripple 1 p p or less Fluctua...

Page 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Page 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Page 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Page 13: ...g term use please adjust in the next way Remove the terminal cover and VR cap before adjustment and attach the VR cap and terminal cover after adjustment 1 For the output load connect an actual load w...

Page 14: ...D 400 to 0 to LAG 400var Z Other Z Other Rated current Output Output load range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0...

Page 15: ...t Output load range Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0 5 to 1V F DC80 to 264V 3 Power transmission DC0 to 2 5 to 5V...

Page 16: ...oad range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V...

Page 17: ...ge Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V 600 or...