7.5 EMC 

 

Item 

Specification 

Electrostatic 
discharge immunity 
test 

Contact discharge 
  ±4kV (Charge voltage) 
Air discharge 
  ±8kV (Charge voltage) 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-2 

Radiated, 
radio-frequency, 
electromagnetic  
field immunity test 

Frequency:① 80 to 1000MHz 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-3 

② 1.4 to 2.0GHz  
③ 2.0 to 2.7GHz 

Field strength:① 10V/m  

② 3V/m  
③ 1V/m 

Amplitude modulation:80%AM (1kHz) 

Electrical fast 
transient / burst 
immunity test 

Power port 
(DC) 

±2.0kV 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-4 

Power port 
(AC) 

±2.0kV 

Signal port  ±1.0kV 

Surge immunity test 

Power port 
(DC) 

Line to ground ±0.5kV 
Line to line   ±0.5kV 

Performance 
standard:B 

After test:Within 
inherent error 

EN61000-6-2 
EN61000-4-5 

Power port 
(AC) 

Line to ground ±2.0kV 
Line to line   ±1.0kV 

Signal port  Line to ground ±1.0kV 

Immunity to conducted 
disturbances, induced 
by radio frequency 
fields 

Frequency:0.15 to 80MHz 
Voltage level:10V, 80%AM (1kHz) 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-6 

Power frequency 
magnetic field 
immunity test 

Frequency:50/60Hz 
Field strength:30A/m 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-8 

Voltage dips, short 
interruptions and 
voltage variations 
immunity tests (AC 
power supply port) 

Residual voltage:0%, 1 cycle 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-11 

Residual voltage:40%, 10/12 cycle 

Performance 
standard:C 

After test:Within 
 inherent error 

Residual voltage:70%, 25/30 cycle 
Residual voltage:0%, 250/300 cycle 

Electromagnetic 
radiation disturbance 

Frequency band 30 to 230MHz, 10m distance:40dB (μV/m) or less 
Frequency band 230 to 1000MHz, 10m distance:47dB (μV/m) or less 

EN61000-6-4 
EN55011 
classA, Group1 

Terminal interference 
voltage 

Power port (AC): 

Frequency band 0.15 to 0.5MHz, Quasi-peak:79dB or less,  

Average   :66dB or less 

Frequency band 0.5 to 30MHz,   Quasi-peak:73dB or less, 

Average   :60dB or less 

Performance standard A:During and after the test the equipment shall be able to continue operation as  

specified. 

Performance standard B:The equipment shall be able to continue operation as specified after the test. 

However, performance degradation during testing is allowed. 

Performance standard C:Temporary loss of function is allowed, but the function can be self-healing or  

can be recovered by operation of the control device. 

 

Summary of Contents for FWVTT2-92A-33

Page 1: ...Q 222 031 INSTRUCTION MANUAL POWER FLOW THREE PHASE REACTIVE POWER TRANSDUCER FWVTT2 92A 33...

Page 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Page 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Page 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 8 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Page 5: ...with a width of 35mm The terminal cover is standard equipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 5 piece set 1 M4 screw 7 piece set 1 4 Mo...

Page 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Page 7: ...orque 1 0 to 1 3 N m Connection diagram AUX SUPPLY P1 1S 3 1 2 S1 1L 3S S2 P2 OUTPUT A B 3L P3 E LOAD Grounding is class D grounding grounding resistance 100 or less If there is a power line that caus...

Page 8: ...be burdened Especially for voltage output products do not short circuit the output This product will not be damaged even if the output terminal is left open in the current output specifications Howev...

Page 9: ...ess 5 3ms DC48V 3 1A or less 5 3ms Note Refer to the specification code for other ratings 7 2 Performance Item Specification Class index 0 5 Response time 1 second or less Ripple 1 p p or less Fluctua...

Page 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Page 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Page 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Page 13: ...g term use please adjust in the next way Remove the terminal cover and VR cap before adjustment and attach the VR cap and terminal cover after adjustment 1 For the output load connect an actual load w...

Page 14: ...D 400 to 0 to LAG 400var Z Other Z Other Rated current Output Output load range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0...

Page 15: ...t Output load range Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0 5 to 1V F DC80 to 264V 3 Power transmission DC0 to 2 5 to 5V...

Page 16: ...oad range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V...

Page 17: ...ge Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V 600 or...

Page 18: ...Hitotsuya 1 chome Adachi ku Tokyo 121 8639 JAPAN TEL 81 3 3885 2411 FAX 81 3 3858 3966 Kyoto Office 1 19 Ichinobe Nishikawahara Jyoyou shi Kyoto 610 0114 JAPAN TEL 81 774 55 1391 FAX 81 774 54 1353 R...

Reviews: