6. CONNECTION PROCEDURE (continued)
6.4 Connecting of the Gas Hose
WARNING
●
You may suffer from danger of suffocation caused by lack of oxygen when
shield gas keeps drifting in a closed place. Be sure to turn off the shield gas
at the main when the welding power source is not in use.
WARNING
●
Be sure to connect the gas hose after fixing to the stand, as physical injuries may result
from falling down of gas cylinder.
●
Attach a proper gas flow rate regulator to the gas cylinder. Failure to observe the demand
may result in physical injuries. The gas flow rate regulator for high pressure gas must be
used.
How to Make Gas Connection
1. Firmly connect the gas hose to the gas supply inlet located on the rear side of the wire feeder.
2. Mount the gas flow rate regulator on the gas cylinder by tightening the nut for attaching the gas
cylinder .
3. Connect the gas hose to the gas supply outlet on the gas flow rate regulator.
NOTE: Firmly tighten the nuts using a monkey wrench, etc. to connect the gas hose and gas
flow rate regulator.
Gas cylinder
Gas flow rate regulator
Gas inlet