VTNS1060A

When installing a VDP system in an apartment/business setting, several modules are available. Each module has an IN and OUT 

connection, this links the various modules together. Regardless of which modules are to be used, the camera unit is always the master 

and is the first device in the chain.

VTO2000A-C

VTO2000A-B

VTO2000A-K

Link Wire

Link Wire

24v PoE

Apartment 1

24v PoE

Apartment 2

24v PoE

Apartment 3

24v PoE

VTO Module Configuration

With  a  PC  or  Laptop  connected  to  the  network  switch,  run  the  Dahua  config  tool  to  find  the  VTO  unit.  By  default  the  VTO 

has  an  IP  address  of  192.168.1.110,  this  can  be  changed  if  required  via  the  config  tool  or  within  the  VTO  web  browser.

 

Login to the VTO via the computers web browser. 

Username: 

admin  

Password: 

admin

Select the 

Local Config

 tab and change 

Device Type

 to 

Modularize Villa

 click 

Ok

 to save the setting.

Select the 

Logout

 option on the left menu and click 

Reboot Device

, this will restart the VTO.

Modular System Configuration

Tel: +44 (0)1457 874 999  |  Fax: +44 (0)1457 829 201  |  Email: [email protected]  |  Online: www.cop-eu.com

Summary of Contents for VTO2000A Series

Page 1: ...Official UK distribution partner tel 44 0 1457 874 999 fax 44 0 1457 829 201 email sales cop eu com web www cop eu com FEBRUARY 2017 VIDEO DOOR ENTRY Quick Install Guide...

Page 2: ...PoE 24v PoE Tamper Switch Sounds an alarm in the event that the VTO unit is tampered with Network Connection Connect the supplied RJ45 adapter cable to this port 12 24v Used when not powering the VTO...

Page 3: ...t the VTO VTH Monitor Configuration To configure the VTH unit use the built in menu within the monitor itself VTH units do not support web browser configuration Select Settings Project Settings and in...

Page 4: ...ddress and set Enable Status to ON To add the VTH to the VTO revisit the VTO web browser and go to System Config Indoor Manager Add Input a family name first name and Nickname these are purely for ref...

Page 5: ...unit first configure the network address within the same range as both the VTO and existing VTH units Go to Project Settings Product Info and select Master this will change the VTH to Extension mode I...

Page 6: ...for the app in your relative app store iDMSS Free iPhone gDMSS Free Android Phone iDMSS HD Free iPad gDMSS HD Free Android Tablet Connect using the app 1 Open DMSS app 2 Select Door 7 Select Push Noti...

Page 7: ...onfiguration With a PC or Laptop connected to the network switch run the Dahua config tool to find the VTO unit By default the VTO has an IP address of 192 168 1 110 this can be changed if required vi...

Page 8: ...Local Config Fascade Layout Click the Plus symbol in the location of the next module then select the module type Multiple modules can be aded to the layout Click Save to confirm the settings then sel...

Page 9: ...the Room No field input the room number such as 1 for apartment 1 Select Settings and then Project Settings in the project settings menu select NetSet to configure the VTH network settings When confi...

Page 10: ...rm the setting Repeat the process for additional monitors each time setting the monitor to a unique IP address and Room Number To program the module buttons go to System Config Local Config Facade Lay...

Page 11: ...add it to the layout as described on page 8 The keypad module has two primary functions calling and password entry To make a call to a specific room simply enter the room number followed by the phone...

Page 12: ...Cop Security Delph New Road Dobcross Oldham OL3 5BG...

Reviews: