Local Configurations
156
Configure the settings for the local alarms. See Table 5-46.
Parameter
Description
Alarm In
Select the channel number.
Alarm Name
Enter the customized alarm name.
Enable
Enable or disable the local alarm function.
Type
In the
Type
list, select
NO
or select
NC
as the voltage output type.
Period
Click
Setting
to display setting interface.
Define a period during which the motion detection is active. For details,
see "Setting Motion Detection Period" section in "5.10.1.1 Configuring
Motion Detect Settings."
Anti-Dither
Configure the event detection lasting time. The system records only
one event during this period. The value ranges from 5 seconds to 600
seconds.
Alarm Out
Click
Setting
to display setting interface.
General Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
External Alarm: Enable alarm activation through the connected
alarm box.
Wireless Siren: Enable alarm activation through devices
connected by USB gateway or camera gateway.
Latch
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300
seconds, and the default value is 10 seconds.
Summary of Contents for Smart 1U
Page 1: ...DIGITAL VIDEO RECORDER User s Manual V1 0 0...
Page 30: ...Connecting Basics 20...
Page 80: ...Local Configurations 70 No Icon Description...
Page 181: ...Local Configurations 171 Select the Enable check boxes to enable IoT function See Figure 5 152...
Page 234: ...Local Configurations 224...
Page 280: ...Glossary 270 Abbreviations Full term VGA Video Graphics Array WAN Wide Area Network...
Page 298: ...Earthing 288...