background image

 

 

20 

5

 

CORNER MOUNT BRACKET INSTALLATION  

5.1

 

Component Installation  

The corner mount bracket needs to be used with a junction box, please refer to Figure 5-1 for the 

accessories which are needed for installation.  

 

Figure 5-1 

5.2

 

Corner Mount Bracket Installation Steps  

5.2.1  Installation Requirements  

The corner mount speed dome can be installed in the hard construction wall in the indoor or 

outdoor environments where there is a 90

 angle.  Before the installation, please make sure: 

 

The wall is thick enough to install the expansion bolts.  

 

The wall can at least sustain the 8x weight of the speed dome.  

 

5.2.2  Installation Steps  

Step 1  

Please draw punching position in the wall with a 90-degree angle according to the mounting 

holes of the corner mount accessories. Then you can dig holes and insert M8 expansion bolts. 

Pull the integration cable through the center hole on the bottom of the corner mount bracket and 

reserve enough cable connection length and then use the M8 expansion bolts to secure the 

corner mount bracket chassis on the wall firmly, finally cover the outlet hole with silicon sealant to 

make it sealed and waterproof. Please refer to Figure 5-2 for more details. 

 

Summary of Contents for SD60-***-SL Series

Page 1: ...Anti corrosion Intelligent Speed Dome Installation Manual Version 1 0 0 ...

Page 2: ...3 2 2 Open the Device 3 2 3 Dial Switch Setup 4 2 3 1 Dial Switch Address and Function 4 2 3 2 Dial Switch Setup 5 2 3 3 Address Setup 5 2 3 4 Baud Rate Parity Setup HD SD Video Mode Setup 6 2 3 5 Terminal Matched Resistance Setup 7 2 4 SD Card Installation Network Speed Dome 8 2 5 Speed Dome Installation 8 Note 8 2 5 1 Cable Connection 8 2 5 2 Junction Box and Protection Tube Installation 10 2 5 ...

Page 3: ...s 18 4 2 2 Installation Steps 18 5 CORNER MOUNT BRACKET INSTALLATION 20 5 1 Component Installation 20 5 2 Corner Mount Bracket Installation Steps 20 5 2 1 Installation Requirements 20 5 2 2 Installation Steps 20 6 POLE MOUNT BRACKET INSTALLATION 23 6 1 Component Installation 23 6 2 Pole Mount Bracket Installation Steps 23 6 2 1 Installation Requirements 23 6 2 2 Installation Steps 23 7 APPENDIX Ⅰ ...

Page 4: ...e 27 8 3 The Problem in Practical Use 27 8 4 RS485 Bus FAQ 28 9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 29 10 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN THE 12V DC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 31 11 APPENDIX IV WIRE GAUGE REFERENCE SHEET 33 ...

Page 5: ...iv Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product ...

Page 6: ... appliances shall have the enough capacity to reach the installation height The lifting appliances shall have safe performance The precaution measures include two types Warning and Note Warning It is to alert you there is an optional risk of death or series injury Note It is to alert you there is an optional risk of damage or property loss Warning 1 All installation and operation here should confo...

Page 7: ...al injury or device damage resulting from opening the shell Please contact your local retailer if there is internal setup or maintenance requirement We are not liable for any problems caused by unauthorized modifications or attempted repair 4 Do not allow other object falling into the device Please make sure there is no metal or inflammable explosive substance in the speed dome The above mentioned...

Page 8: ... Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for a long time It may result in paint flake It is highly recommended to use the product with a lightning proof device which can realize better lightning proof effect ...

Page 9: ...e ceiling wall and the bracket can sustain the 8X weight of the speed dome and its installation components Please make sure the wall is thick enough to install expansion bolts need to be purchased Please notice that the installation height should be more than 6m if it is a laser speed dome 1 3 Cable Requirements 1 3 1 Video Cable Requirements The minimum video cable requirements are as follows 75 ...

Page 10: ...2 1 3 2 Power Supply Cable Requirements Refer to appendix 3 for AC 24V power supply device Refer to appendix 4 for DC12V power supply device ...

Page 11: ...ist Please make sure all the components are included please refer to the packing list for more details 2 2 Open the Device Step 1 Please open the box and then take out the speed dome See Figure 2 1 Figure 2 1 Step 2 Use the screw to dismantle the bracket components take out the filling material around the module which is shown in Figure 2 2 ...

Page 12: ... speed dome and HDCVI speed dome are different which will be introduced respectively 2 3 1 1 Analog Speed Dome Dismantle the bracket component you can see there are two dial switches on the PTZ mainboard You can use them to set speed dome address baud rate and parity Please refer to Figure 2 3 for the dial switch address Figure 2 3 ...

Page 13: ...he power and reboot the device after relevant information has been set again which can make the new settings take effect There are two dial switch on the speed dome PTZ which are used to confirm the speed dome address baud rate parity or HD SD vide mode It is 1 when you set the button as ON For address setup dial switch 1 is the lowest bit 8 is the highest bit for the Baud rate parity or HD SD vid...

Page 14: ...and parity 1 and 2 bits are used to set Baud rate while 3 and 4 bits are used to set parity see Figure 2 6 for the labels of Baud rate and parity see sheet 2 2 and 2 3 for settings of baud rate and parity Figure 2 6 Please refer to the baud rate setup sheet 2 2 for detailed information 1 2 Baud rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Sheet 2 2 Please refer to the parity se...

Page 15: ...ed on the power board There are two connection modes which are shown in Figure 2 8 Figure 2 8 The factory default connection mode is shown in Figure 2 9 the jumper connection board is plugged into pin 2 and pin 3 which means 120Ω resistance is not connected to the device Figure 2 9 If you want to connect the 120Ω resistance you have to pull the jumper out of pin 2 and pin 3 and connect to pin 1 an...

Page 16: ...me etc There are various types of brackets for speed dome to meet the application requirements of different environments Please refer to chapter 3 to chapter 6 for more details about speed dome installation Here we are going to install the analog speed dome with the analog speed dome wall mounted bracket 2 5 1 Cable Connection The speed dome is equipped with a multi function combination cable whic...

Page 17: ...eed dome to the quick installation connector connect the integration cable reserved by the wall mounted bracket to the multi function combination cable of the speed dome according to the requirements and then use the insulated rubber tape to twist the connection joints respectively to make it waterproof which is shown in Figure 2 13 Figure 2 13 Note ...

Page 18: ...e 2 14 The junction box shall be used together with the protection tube the installation steps are shown as follows Step 1 Use expansion bolts and screws to fix the junction box on the wall Step 2 Cover the cable with protection tube component in advance take down the threaded connector and the plug and seal ring of the junction box keep the seal ring of the junction box well for future use Step 3...

Page 19: ...11 Figure 2 15 The installation result is shown in Figure 2 16 Figure 2 16 2 5 3 Install Speed Dome ...

Page 20: ... the pre hung screw stuck tightly with the hanging hook Step 5 Screw three M6 14 stainless screws on the bracket into the groove of the speed dome flange use inner hex tool to fasten the three pre hung stainless screws on the speed dome which is shown in Figure 2 17 Figure 2 17 Step 6 Check if the three stainless screws on the quick installation connector are tightened well make sure the speed dom...

Page 21: ...13 Figure 2 18 ...

Page 22: ...4 3 Component Dimension 3 1 Junction Box Please refer to Figure 3 1 for the dimension of junction box Figure 3 1 3 2 Wall Mount Bracket Please refer to Figure 3 2 for the dimension of wall mount bracket ...

Page 23: ...15 Figure 3 2 3 3 Corner Mount Bracket Please refer to Figure 3 3 for the dimension of corner mount bracket ...

Page 24: ...16 Figure 3 3 3 4 Pole Mount Bracket Please refer to Figure 3 4 for the dimension of pole mount bracket ...

Page 25: ...17 Figure 3 4 ...

Page 26: ...enough to install the expansion bolts The wall can at least sustain the 8x weight of the speed dome bracket and some other accessories 4 2 2 Installation Steps Step 1 Please draw the punch position in the wall according to the mounting holes on the bottom of the wall mount bracket Then you can dig holes and insert the expansion bolts into the holes you just dug Use four hex bolts and flat washer t...

Page 27: ...igure 4 2 Step 2 Install the speed dome onto the wall mount bracket Please refer to Figure 4 3 for more details Please refer to Chapter 2 6 Speed Dome Installation for detailed installation modes Figure 4 3 ...

Page 28: ... is thick enough to install the expansion bolts The wall can at least sustain the 8x weight of the speed dome 5 2 2 Installation Steps Step 1 Please draw punching position in the wall with a 90 degree angle according to the mounting holes of the corner mount accessories Then you can dig holes and insert M8 expansion bolts Pull the integration cable through the center hole on the bottom of the corn...

Page 29: ...21 Figure 5 2 Step 2 Install a junction box on the corner mount bracket Step 3 Install speed dome according to Figure 5 3 please refer to Chapter 2 6 for more details about speed dome installation ...

Page 30: ...22 Figure 5 3 ...

Page 31: ...he installation please make sure The pole bracket can sustain the 8X weight of the speed dome The diameter of the pole structure shall conform to the installation dimension of the clamp Default factory clamp is 5 inches for the column of φ80 130mm It can work with the pole mount bracket You can adjust the diameter and the value clamp specification is φ59 82mm φ84 108mm φ80 130mm φ130 152mm φ155 17...

Page 32: ...e outlet hole to make it sealed and waterproof Figure 6 2 Note After the installation please make sure the clamp is firmly fastened in case it may result in broken clamp Step 2 Install a junction box on the pole mount bracket Step 3 Please refer to Figure 6 3 for installation refer to Chapter 2 6 Speed Dome Installation for detailed installation modes ...

Page 33: ...25 Figure 6 3 ...

Page 34: ...point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to you...

Page 35: ...ax transmission distance shall become longer 8 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 8 1 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jammi...

Page 36: ...on cable is loose RS485 Bus connection are cut off Modify host or speed dome setup Switch RS485 positive end and negative end Fix connection cable firmly Replace RS485 Bus I can control the speed dome but is not smooth RS485 Bus connection are not good One RS485 bus is off The distance between host and speed dome is too far Parallel connected too much speed domes Connect RS 485 Bus again Replace R...

Page 37: ...2 13 37 23 190 83 58 16 298 17 90 88 763 31 232 66 25 97 70 29 78 152 66 46 53 238 53 72 71 610 65 186 13 30 81 42 24 82 127 22 38 78 198 78 60 59 508 87 155 10 35 69 79 21 27 109 04 33 24 170 38 51 93 436 18 132 95 40 61 06 18 61 95 41 29 08 149 08 45 44 381 66 116 33 45 54 28 16 54 84 81 25 85 132 52 40 39 339 25 103 40 50 48 85 14 89 76 33 23 27 119 27 36 35 305 32 93 06 55 44 41 13 54 69 39 21...

Page 38: ...30 mm Feet m w 0 8000 1 000 1 250 2 000 100 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 ...

Page 39: ...55 20 30 53 9 31 47 71 14 54 74 54 22 72 190 83 58 16 25 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 30 20 35 6 20 31 80 9 69 49 69 15 15 127 22 38 78 35 17 45 5 32 27 26 8 31 42 60 12 98 109 04 33 24 40 15 27 4 65 23 85 7 27 37 27 11 36 95 41 29 08 45 13 57 4 14 21 20 6 46 33 13 10 10 84 81 28 85 50 12 21 3 72 19 08 5 82 29 82 9 09 76 33 23 27 55 11 10 3 38 17 35 5 29 27 11 8 26 69 39 21 15 6...

Page 40: ...32 mm Feet m w 0 8000 1 000 1 250 2 000 100 6 11 1 86 9 54 2 91 14 91 4 54 38 17 11 63 ...

Page 41: ...0 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 29 0 09621 0 400 26 28 0 1257 0 450 25 0 1602 0 560 24 24 0 2463 0 600 23 23 0 2827 0 710 22 22 0 3958 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7663 2...

Page 42: ...tware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...