22
Figure 4-8
Please refer to the following sheet for detailed information.
Parameter
Function
Max
connection
It is the max Web connection for the same device. The value ranges from 1
to 20. The max connection amount is 20.
TCP port
The default value is 37777. You can input the actual port number if
necessary.
UDP port
The default value is 37778. You can input the actual port number if
necessary.
HTTP port The default value is 80. You can input the actual port number if necessary.
RTSP port The default value is 554. Rtsp streay query format is:
Main stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0
Sub stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=1
You need to input the following four items manually.
Username/password/IP and port.
The IP is device IP and the port default value is 554. You can leave it in
blank if it is the default value.
You do not need to input the user name and password if you do not need
to the verification. Such as:
rtsp://ip:port/cam/realmonitor?channel=1&subtype=0
Summary of Contents for IPC-HFW2100N Series
Page 1: ...Cost effective HD IR Waterproof Fixed IP Camera Quick Start Guide Version 1 0 1...
Page 6: ...2 Figure 1 3...
Page 8: ...4 Figure 2 2...
Page 14: ...Cost effective HD IR Waterproof Fixed IP Camera User s Manual Version 1 0 2...
Page 23: ...5 Figure 2 2 Figure 2 3...
Page 25: ...7 Figure 3 2...
Page 31: ...IPC Web Operation Manual Version 3 0 0...
Page 58: ...25 Figure 4 11 4 2 6 SMTP e mail The SMTP interface is shown as in Figure 4 12 Figure 4 12...
Page 67: ...34 Figure 4 20 Figure 4 21...
Page 74: ...41 Figure 4 28 Figure 4 29 Figure 4 30...
Page 93: ...software NOT FOR SALE...