background image

User’s Manual   

3 Appearance 

Figure 3-1 Appearance 

 

Table 3-1 Structure 

No. 

Name 

Description 

Button 

  Press and hold both buttons at the same time for 8 

seconds, and then the system enters pairing mode. 

 

Flashes green quickly: Pairing. 

 

Solid green for 2 seconds: Pairing successful. 

 

Slowly flashes green for 3 seconds: Pairing failed. 

  On the normal status, press both buttons together 

once, and then the button sends alarm messages to 
the hub. 

 

Flashes green once: Sending messages to the hub. 

 

Flashes green for 0.5 seconds: Successfully sent 
messages to the hub. 

 

Flashes red for 0.5 seconds: Failed to send 
messages to the hub.   

  In accidental press protection mode, press and hold 

both buttons together for 2 seconds, and then alarm 
messages will be sent to the hub. 
The indicator status in accidental press protection 
mode is the same as that of the normal status. 

 

Make sure that you have enabled the accidental press 
protection function on the DMSS app. 

Indicator 

Summary of Contents for DHI-ARD822-W2

Page 1: ...Wireless Panic Button User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V1 0 0...

Page 2: ...if not avoided could result in property damage data loss reductions in performance or unpredictable results TIPS Provides methods to help you solve a problem or save time NOTE Provides additional info...

Page 3: ...ge without prior written notice Product updates might result in some differences appearing between the actual product and the manual Please contact customer service for the latest program and suppleme...

Page 4: ...ements Connect the device to the adapter before power on Strictly abide by local electrical safety standards and make sure that the voltage in the area is steady and conforms to the power requirements...

Page 5: ...nd Warnings III 1 Introduction 1 1 1 Overview 1 1 2 Technical Specifications 1 2 Checklist 3 3 Appearance 4 4 Adding the Button to the Hub 5 5 Installation 6 6 Configuration 7 6 1 Viewing Status 7 6 2...

Page 6: ...e ones that correspond with your model Table 1 1 Technical specifications Type Parameter Description Function Indicator Light 1 for multiple statuses pairing communication and more Button 1 Remote Upd...

Page 7: ...ions 55 mm 36 mm 14 2 mm 2 17 1 42 0 56 L W H Packaging Dimensions 95 mm 59 5 mm 30 5 mm 3 74 2 34 1 20 L W H Installation Wall mount handheld Net Weight 18 g 0 04 lb Gross Weight 48 g 0 11 lb Certifi...

Page 8: ...hecklist Figure 2 1 Checklist Table 2 1 Checklist No Item Name Quantit y No Item Name Quantity 1 Panic button 1 4 Bracket Optional 1 2 Quick start guide 1 5 Screw package Optional 1 3 Legal and regula...

Page 9: ...r once and then the button sends alarm messages to the hub Flashes green once Sending messages to the hub Flashes green for 0 5 seconds Successfully sent messages to the hub Flashes red for 0 5 second...

Page 10: ...that the hub has a stable internet connection Make sure that the hub is disarmed Step 1 Go to the hub screen and then tap to add the button Step 2 Tap to scan the QR code at the bottom of the panic b...

Page 11: ...tton supports wall mount and can be handheld This section uses wall mount as an example You need to buy a bracket to install the button Figure 5 1 Installation Step 1 Drill 2 holes in the wall accordi...

Page 12: ...r later and the button is V1 000 0000001 0 R 20211203 or later Battery Level The battery level of the button Fully charged Sufficient Moderate Insufficient Low Operation Mode The working mode of the b...

Page 13: ...ub and alert with siren Alarm video Linkage When an alarm is triggered the accessories will report the alarm events to the hub and then will link events Video Channel Select the video channel as neede...

Page 14: ...ystem is equipped with the latest security patches and fixes When the device is connected to the public network it is recommended to enable the auto check for updates function to obtain timely informa...

Page 15: ...cessary it is highly recommended that you use safe modes including but not limited to the following services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMT...

Page 16: ...on requirements between two sub networks it is suggested to use VLAN network GAP and other technologies to partition the network so as to achieve the network isolation effect Establish the 802 1x acce...

Page 17: ...User s Manual...

Page 18: ...l t a en d ti a a u l n c e are m a d t a e riale n u p e i s e t rd e e e ri vita d t e date performante mai s zute sau rezultate imprevizibile OO SFATURI Ofera metode care sa va ajute sa rezolvati...

Reviews: