User's Manual
28
Parameter
Description
Monitoring Station
Enable
Monitoring Station
, and then set the SIA protocol parameters
for the alarm receiving center (ARC).
●
Preferred IP address
: Enter the IP address and port number of the
ARC.
●
Alternative IP address
: Enter the alternative IP address and port
number of the ARC.
◇
Messages will be sent to the alternative IP address only when
the preferred IP address fails to receive the message.
◇
If
Heartbeat interval
is enabled, the system will judge whether
to send the message to the preferred or alternative IP address.
●
IP Protocol
: Select
TCP
by default.
●
Heartbeat interval
: Set the heartbeat interval with the range from
0 second to 24 hours (60 seconds by default).
0 seconds means
Heartbeat interval
is disabled.
●
Central account
: Enter the account number that created by the
ARC, which is to be used to identify the hub when the hub sends
information to the ARC.
●
Encryption
: The hub uses an encryption format for information
security when you configure the ARC.
AES128
is set by default.
●
Upload event
: Tap
next to an event to upload it.
◇
Alarm
: Alarm message.
◇
Error
: Power failure, battery undervoltage, tamper, and offline.
◇
Event
: Prohibit the use of peripherals, add or delete peripherals,
and add or delete users.
◇
Arm/Disarm
: Message notifications of arming and disarming
the system.
4.6.3 Fixing Errors
You can fix errors after abnormal devices are checked. Errors are found in two ways, including device
automatic reporting and manual checking.
Step 1
On the
Home
screen, select
Pending Task
>
Error Fixing
.
Step 2
In the error list, tap an error task, and then tap
Start processing
.
Step 3
Fix the error according to the suggestions.
Step 4
Tap
Error Fixed
if the error is fixed, and then wait for the customer to confirm it.