background image

 

 

 

 

 

 

 

 

 

Intelligent Speed Dome Installation Manual  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                               Version 1.0.1

 

 

Summary of Contents for DH-SD60230U-HNI

Page 1: ...Intelligent Speed Dome Installation Manual Version 1 0 1 ...

Page 2: ... Matched Resistance Setup 5 1 5 Dial Switch Setup HDCVI Intelligent Speed Dome 6 1 5 1 Initial Setup 6 1 5 2 Dial Switch Setup for Intelligent Speed Dome 6 1 5 3 Baud rate and HD SD Video Format Setup 6 1 5 4 Speed Dome Address Setup 7 1 5 5 Terminal Matched Resistance Setup 7 1 6 SD Card Installation Network Speed Dome Module 9 1 7 Reset and SD Card Installation Network Speed Dome 9 1 8 Speed Dom...

Page 3: ...tion 17 3 2 1 Installation Requirements 17 3 2 2 Installation Steps 17 4 HANG MOUNT BRACKET INSTALLATION 19 4 1 Component Installation 19 4 2 Installation 19 4 2 1 Installation Requirements 19 4 2 2 Installation Steps 19 5 CORNER MOUNT BRACKET INSTALLATION 22 5 1 Component Installation 22 5 2 Installation 22 5 2 1 Installation Requirements 22 5 2 2 Installation Steps 22 6 POLE MOUNT BRACKET INSTAL...

Page 4: ... 29 8 1 RS485 Bus Main Feature 29 8 2 RS485 Bus Transmission Distance 29 8 3 The Problem in Practical Use 29 8 4 RS485 Bus FAQ 30 9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 31 10 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN THE 12V DC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 33 11 APPENDIX IV WIRE GAUGE REFERENCE SHEET 35 ...

Page 5: ...iv Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product ...

Page 6: ...ch the installation height The lifting appliances shall have safe performance The precaution measures include two types Warning and Note Warning It is to alert you there is an optional risk of death or series injury Note It is to alert you there is an optional risk of damage or property loss Warning 1 All installation and operation here should conform to your local electrical safety codes We assum...

Page 7: ...ify the device There is risk of personal injury or device damage resulting from opening the shell Please contact your local retailer if there is internal setup or maintenance requirement We are not liable for any problems caused by unauthorized modifications or attempted repair 4 Do not allow other object falling into the device Please make sure there is no metal or inflammable explosive substance...

Page 8: ... Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for a long time It may result in paint flake It is highly recommended to use the product with a lightning proof device which can realize better lightning proof effect ...

Page 9: ...ponding bracket Please make sure the ceiling wall and the bracket can support the speed dome and its corresponding installation component It shall sustain the 8X weight of the speed dome Please notice that the installation height should be more than 6m if it is a laser speed dome About cable Please select the cable according to your transmission distance The minimum video coaxial cable requirement...

Page 10: ...l may result in device damage during the transportation 1 2 Check Accessories Before the installation please check the accessories one by one according to the packing list Please make sure all the components listed are includes 1 3 Open the Device Please open the box and then take out the speed dome See Figure 1 1 Figure 1 1 Note There are two types of intelligent speed dome which are shown in Fig...

Page 11: ...rolling it Only after all these setup can the speed dome respond to its control commands Note Users must reboot the speed dome after resetting some specifications which makes the new setup take effect There are two dial switch buttons on the speed dome PTZ which are used to confirm the specifications of address and Baud rate parity It is 1 when you set the button as ON For address setup dial 1 is ...

Page 12: ... rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Sheet 1 1 Please refer to the parity setup sheet 1 2 for detailed information 3 4 Parity OFF OFF NONE ON OFF EVEN OFF ON ODD ON ON NONE Sheet 1 2 1 4 4 Speed Dome Address Setup Figure 1 5 See Figure 1 5 for address setup The speed dome uses dial switch to set address the encode mode adopts binary system 1 to 8 is valid bit The highe...

Page 13: ...minal Matched Resistance Setup The connection mode of device terminal 120Ω resistance is equipped on the power board There are two connection modes which are shown in Figure 1 6 120Ω 1 2 ON 2 3 OFF Figure 1 6 The factory default connection mode is shown in Figure 1 7 the jumper connection board is plugged into pin2 and pin 3 which means 120Ω resistance is not connected to the device Figure 1 7 If ...

Page 14: ...t reboot the speed dome after resetting some specifications which makes the new setup take effect There are two dial switch buttons on the speed dome PTZ which are used to confirm the specifications of address and Baud rate HD SD video format It is 1 when you set the button as ON For address setup dial 1 is the lowest bit 8 is the highest bit for the Baud rate and HD SD video format setup dial 1 i...

Page 15: ...em 1 to 8 is valid bit The highest address bit is 255 You can refer to the following sheet 1 3 for more information Address 1 2 3 4 5 6 7 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF ...

Page 16: ...ion board is plugged into pin2 and pin 3 which means 120Ω resistance is not connected to the device Figure 1 13 If you want to connect the 120Ω resistance you have to pull the jumper out of pin 2 and pin 3 and connect to pin 1 and pin 2 then 120Ω resistance is connected to the circuit see Figure 1 14 Figure 1 14 ...

Page 17: ... 1 15 Micro SD card can be used for data storage Figure 1 15 1 7 Reset and SD Card Installation Network Speed Dome You can see there is a RESET button and Micro SD card slot on the PTZ mainboard after you remove the bracket component See Figure 1 16 Reset button is used to reset network system Micro SD card is used to store the data Figure 1 16 1 8 Speed Dome Installation Note ...

Page 18: ...d the screw thread of the quick installation port and turn it into the screw thread of the wall mount bracket Use M4 stainless screws to secure firmly See Figure 1 17 Figure 1 17 1 8 2 Cable Connection Connect the safety hook of the intelligent speed dome cover to the hook of the quick installation port Connect the reserved integration cable of the wall mount bracket to the corresponding power cab...

Page 19: ...he straight edge of the flange of the intelligent speed dome to the straight edge of the quick installation port and then push the intelligent speed dome to the bottom of the port slowly Step 3 Use your hands to turn the quick installation port M6 14 stainless screw with spring washer to the Ф6 5 hole of the straight edge of the intelligent speed dome Turn other two M6 14 stainless screws to groov...

Page 20: ...hree stainless screws of the quick installation port are firmly secured The intelligent speed dome is fixed The speed dome is straight The safety hook connection is firm After your installation the interface is shown as in Figure 1 20 Figure 1 20 ...

Page 21: ... DIMENSIONS 2 1 Wall Mount Bracket The wall mount bracket dimensions are shown as below See Figure 2 1 Figure 2 1 2 2 Hanging Mount Bracket Length Optional The hanging mount bracket is shown as below See Figure 2 2 ...

Page 22: ...ure 2 2 Note The bracket length adjustable range is 200mm default 400mm optional You just need to replace the connection pole 2 3 Corner Mount Bracket The corner mount bracket is shown as below See Figure 2 3 ...

Page 23: ...15 Figure 2 3 2 4 Pole Mount Bracket The pole mount bracket is shown as below See Figure 2 4 ...

Page 24: ...16 Figure 2 4 ...

Page 25: ...r environments Before the installation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 8x weight of the speed dome 3 2 2 Installation Steps Step 1 See Figure 3 2 Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Us...

Page 26: ...18 Figure 3 2 Step 2 Install the intelligent speed dome in the bracket See Figure 3 3 Please refer to 1 7 Speed Dome Installation for more details Figure 3 3 ...

Page 27: ...ronments Before the installation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 8x weight of the speed dome 4 2 2 Installation Steps Step 1 Loosen the M4 bolt in the connection plate to separate the connection plate and connection pole Pull the integration cable through the airproof slot of the bottom of the connection plate and then conne...

Page 28: ...ed to paste the silica gel on the surface of the connection plate and the ceiling and the cable exit Step 2 Pull the cable through the connection pole and then secure the connection pole to the connection plate Fix the M4 bolt Push the decoration cover to the bottom See Figure 4 3 Figure 4 3 ...

Page 29: ...ments you need to paste enough Teflon tape at the top screw thread of the connection pole and then turn the connection pole to the connection plate firmly Step 3 Please refer to chapter 1 6 for detailed information about speed dome installation See Figure 4 4 Figure 4 4 ...

Page 30: ...bolt The wall can at least sustain the 8x weight of the speed dome 5 2 2 Installation Steps Step 1 Please draw four holes position in the wall with a 90 degree angle according to the holes of the corner installation accessories See Figure 5 2 Then you can dig four holes according to the holes of the corner mount accessories and insert the M8 expansion bolts Pull the integration cable through the c...

Page 31: ...23 Figure 5 2 Step 2 Install speed dome according to Figure 5 3 please refer to 1 7 for more details about speed dome installation ...

Page 32: ...24 Figure 5 3 ...

Page 33: ...mply with the installation dimension of the clamp Default factory clamp is 5 inches for the column of φ80 130mm It can work with the pole installation bracket You can adjust the diameter and the value clamp specification is φ59 82mm φ84 108mm φ80 130mm φ130 152mm φ155 178mm φ180 203mm φ194 216mm For special dimensions please contact us for more information 6 1 2 Installation Steps Step 1 Please re...

Page 34: ... Note After the installation please make sure the clamp is firmly secure in case it may result in clamp broken Step 2 Please refer to chapter 1 7 for detailed information about speed dome installation See Figure 6 3 ...

Page 35: ...27 Figure 6 3 ...

Page 36: ...ne point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to ...

Page 37: ...ax transmission distance shall become longer 8 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 8 1 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jammi...

Page 38: ...on cable is loose RS485 Bus connection are cut off Modify host or speed dome setup Switch RS485 positive end and negative end Fix connection cable firmly Replace RS485 Bus I can control the speed dome but is not smooth RS485 Bus connection are not good One RS485 bus is off The distance between host and speed dome is too far Parallel connected too much speed domes Connect RS 485 Bus again Replace R...

Page 39: ...2 13 37 23 190 83 58 16 298 17 90 88 763 31 232 66 25 97 70 29 78 152 66 46 53 238 53 72 71 610 65 186 13 30 81 42 24 82 127 22 38 78 198 78 60 59 508 87 155 10 35 69 79 21 27 109 04 33 24 170 38 51 93 436 18 132 95 40 61 06 18 61 95 41 29 08 149 08 45 44 381 66 116 33 45 54 28 16 54 84 81 25 85 132 52 40 39 339 25 103 40 50 48 85 14 89 76 33 23 27 119 27 36 35 305 32 93 06 55 44 41 13 54 69 39 21...

Page 40: ...32 mm Feet m w 0 8000 1 000 1 250 2 000 100 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 ...

Page 41: ...55 20 30 53 9 31 47 71 14 54 74 54 22 72 190 83 58 16 25 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 30 20 35 6 20 31 80 9 69 49 69 15 15 127 22 38 78 35 17 45 5 32 27 26 8 31 42 60 12 98 109 04 33 24 40 15 27 4 65 23 85 7 27 37 27 11 36 95 41 29 08 45 13 57 4 14 21 20 6 46 33 13 10 10 84 81 28 85 50 12 21 3 72 19 08 5 82 29 82 9 09 76 33 23 27 55 11 10 3 38 17 35 5 29 27 11 8 26 69 39 21 15 6...

Page 42: ...34 mm Feet m w 0 8000 1 000 1 250 2 000 100 6 11 1 86 9 54 2 91 14 91 4 54 38 17 11 63 ...

Page 43: ...0 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 29 0 09621 0 400 26 28 0 1257 0 450 25 0 1602 0 560 24 24 0 2463 0 600 23 23 0 2827 0 710 22 22 0 3958 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7663 2...

Page 44: ...tware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...