background image

User's Manual 

Parameter 

Description 

External Detector Status 

Select 

Normally Closed

 or 

Normally Open

 for the external 

detector. 

Alarm Type 

Select an alarm type based on the external detector type, and 
then tap 

OK

 

Intrusion

 

 

Fire Alarm

 

 

Medical Help

 

 

Panic Button

 

 

Gas Alarm

 

Alarm Input Type 

Select an alarm input type for the external detector, and then tap 

OK

 

Detector

 

Tamper

 

For example, if you select 

Tamper

 for the external detector, 

only tamper alarm messages will be sent to the alarm hub. 

LED Indicator 

LED Indicator

 is enabled by default. For details on indicator 

behavior, see "3.1 Appearance". 

 

If 

LED Indicator

 is disabled, the LED indicator will remain off 

regardless of whether the input expander is functioning 
normally or not. 

Signal Strength Detection 

Test the current signal strength. 

Detector Test 

Detect whether the accessory works. 

Transmit Power 

  Select from high, low, and automatic. 

  The higher the transmission power, the farther the 

transmission and the higher power consumption. 

Cloud Update 

Update online. 

Delete 

Delete the online accessory. 

 

Go to the 

Hub

 screen, select the accessory from the list, and then 

swipe left to delete it. 

6.2 Status 

On the 

Hub

 screen, select the input expander as needed from the accessory list to view the status of 

the input expander. 

Summary of Contents for ARM310-W2

Page 1: ...Wireless Input Expander User s Manual V1 0 0...

Page 2: ...e As the device user or data controller you might collect the personal data of others such as their face fingerprints and license plate number You need to be in compliance with your local privacy prot...

Page 3: ...ion of the functions operations and technical data If there is any doubt or dispute we reserve the right of final explanation Upgrade the reader software or try other mainstream reader software if the...

Page 4: ...e Installation Requirements Connect the device to the adapter before power on Strictly abide by local electrical safety standards and make sure that the voltage in the area is steady and conforms to t...

Page 5: ...Foreword I Important Safeguards and Warnings III 1 Introduction 1 2 Checklist 2 3 Design 3 3 1 Appearance 3 3 2 Dimensions 4 4 Connecting to the Hub 5 5 Installation 6 6 Configuration 7 6 1 Configurin...

Page 6: ...uction Wireless input expander is a conversion device that connects to a detector through wired mode and sends the message in wireless mode to the security system It can be set up via the DMSS app for...

Page 7: ...list Figure 2 1 Checklist Table 2 1 Checklist No Item Name Quantity No Item Name Quantity 1 Input expander 1 4 User s manual 1 2 Double sided adhesive tape 1 5 Legal and regulatory information 1 3 Cab...

Page 8: ...nt was triggered Solid green for 2 seconds Pairing successful Slowly flashes green for 3 seconds Pairing failed 2 Peripheral port Connect the peripheral with the alarm cable 3 On Off switch Turn on or...

Page 9: ...User s Manual 4 3 2 Dimensions Figure 3 2 Dimensions mm inch...

Page 10: ...o DMSS Make sure that the hub has a stable internet connection Make sure that the hub is disarmed Step 1 Go to the hub screen and then tap to add the input expander Step 2 Tap to scan the QR code at t...

Page 11: ...d cable into the input expander to connect it to the wired detector Figure 5 1 Installation Table 5 1 Installation items No Item name No Item name 1 Expansion bolt 3 ST3 18 mm self tapping screw 2 Att...

Page 12: ...Protection Zone The accessory located in the 24 h protection zone is always active whether the security system is configured in the armed mode or not Home Mode Enable the home mode and then the selec...

Page 13: ...default For details on indicator behavior see 3 1 Appearance If LED Indicator is disabled the LED indicator will remain off regardless of whether the input expander is functioning normally or not Sign...

Page 14: ...pander Low Weak Good Excellent No Battery Level The battery level of the detector Fully charged Sufficient Moderate Insufficient Low Anti tampering Status Anti tampering status of the input expander O...

Page 15: ...User s Manual...

Page 16: ...l t a en d ti a a u l n c e are m a d t a e riale n u p e i s e t rd e e e ri vita d t e date performante mai s zute sau rezultate imprevizibile OO SFATURI Ofera metode care sa va ajute sa rezolvati...