21
Parameter
Note
Device Type
NO and NC, set according to device.
Record Channel
Select corresponding record channel no., can re-select. When alarm occurs,
system turns on corresponding channel to record.
Record Delay
Set delay, when alarm ends, alarm record will continue for a certain period.
Alarm Output
Alarm link output channel
Snapshot
When alarm occurs, trigger and snapshot the selected channel
Alarm Upload
Upload alarm info
Buzzer
When alarm, enable buzzer to alarm
SMS
When alarm, send SMS to set number
Audio Play
When abnormality occurs, play the selected audio file
Siren Output
Control
When alarm occurs, enable siren.
Call Center
When alarm occurs, report to call center.
Zone Type
Description
Application
Fire Zone
Device will send alarm report to alarm
center.
Not affected by arming/disarming, bypass.
Keypad will show this zone with alarm tone
prompt plus send report to alarm center;
not affected by arming/disarming, cannot
be bypasses. Alarm tone prompt
Mainly used heat
detectors, smoke
detectors
24-hour
Sound
Zone
Self-carried link siren, buzzer, no need to
set
Send alarm report to alarm center.
Not affected by arming/disarming, bypass.
Keypad will show this zone, and send
alarm prompt.
Emergency key
24-hour
Mute Zone
Device does not link alarm, buzzer.
Send report to alarm center.
Not affected by arming/disarming, bypass
Jewelry stores, banks
and other emergency
button
Emergency
Zone
Send report to alarm center.
Not affected by arming/disarming, bypass
Keypad will show this zone, and send
alarm prompt.
Emergency key
In/out Zone
1
Global arm, instant arm cannot provide
entry delay
Out, in mode, provide entry and zone 1
enter delay
After arming, exit delay becomes effective
immediately.
The main entrance
with the keypad
disarming necessary
place
In/out Zone
2
Global arm, instant arm cannot provide
entry delay
Out, in mode, provide entry and zone 2
enter delay
After arming, exit delay becomes effective
immediately.
The main entrance
with the keypad
disarming necessary
place
Internal
Zone
Home Arm and instant arm, internal zone
will be bypassed.
When out arm, provide entry zone 1 entry
delay and exit delay.
Global arm, no entry delay, but has exit delay.
Hall, lounge detectors
can be installed
indoors
External
After arming takes effect, no entry or exit delay
Windows, fences,