background image

Operation and Daily Maintenance  

 

Do not touch the heat dissipation component of the unit. This part of the unit is hot and may 

cause a burn.  

 

Do not open or dismantle the device; there are no components that a user can fix or replace. 

Opening the unit may cause water leakage or expose components to direct light. Contact the 

manufacturer or a qualified service representative to service the camera or to replace a 

component, including the desiccant. 

 

Dahua recommends the use of a thunder-proof device in concert with the unit. 

 

Do not touch the CCD or the CMOS optic sensor. Use a blower to clean dust or dirt on the lens 

surface. Use a dry cloth dampened with alcohol and gently wipe away any dust on the lens.  

 

Use a dry soft cloth to clean the unit’s housing. If the unit is particularly dusty, use water to dilute 

a mild detergent, apply the diluted detergent to a soft cloth, then gently clean the device. Finally, 

use a dry cloth to wipe the unit dry. Do not use a volatile solvent like alcohol, benzene, or thinner; 

or use a strong detergent with abrasives, which may damage the surface coating or reduce the 

working performance of the unit. 

 

Do not touch or wipe a dome cover during installation, this cover is an optical device. Refer to 

the following methods clean the dome cover:  

  Stained with dirt: Use an oil-free soft brush or blower to gently remove the dirt. 

  Stained with grease or fingerprints: Use a soft cloth to wipe gently the water droplet or the oil 

from the dome cover. Then, use an oil-free cotton cloth or paper soaked with alcohol or 

detergent to clean the lens from the center of the dome to outside. Change the cloth several 

times to ensure the dome cover is clean. 

Warnings 

 

Change the default password after the initial login to protect the integrity of the network. 

 

Use the standard accessories provided by the manufacturer and ensure the unit is installed and 

commissioned by qualified professionals.  

 

Protect the lens area from laser radiation when using a laser device to aid in installation and 

leveling of the unit. 

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Summary of Contents for A83ABBZ

Page 1: ...4K HDCVI Vari focal Bullet Camera A83ABBZ Quick Start Guide Version 001 001 Dahua Technology USA Inc Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...

Page 2: ...3 Legal Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 4 2 Unpacking 5 3 Installation and Configuration 6 3 1 Framework and Dimensions 6 3 2 Camera and Cables 6 Cable Connections 6 4 Device Instal...

Page 3: ...environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have power supplied to the unit whenever the power cord...

Page 4: ...not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of the CCD or the CMOS sensor Transport use and sto...

Page 5: ...a strong detergent with abrasives which may damage the surface coating or reduce the working performance of the unit Do not touch or wipe a dome cover during installation this cover is an optical devi...

Page 6: ...user guide is the intellectual property of Dahua Technology Company LTD and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are l...

Page 7: ...container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view t...

Page 8: ...ceives an analog audio input signal 2 POWER IN Input from a 12 VDC or 24 VAC power supply Use in accordance with device label instructions 3 12 VDC POWER OUT Supplies 12 VDC power to another device ma...

Page 9: ...and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building...

Page 10: ...th the TOP of the mounting template 7 Route the cables from the camera through the installation medium 8 Align the four 4 holes on the camera body with the expansion bolts 9 Insert a self tapping scre...

Page 11: ...the on screen menu and to select menu items Use the Left and Right buttons to zoom the lens Use the Up and Down buttons to focus the camera manually 4 Right 5 Down 6 Left 3 Middle Confirm selection 7...

Page 12: ...e Setting Then select the System tab and select the PTZ link on the left side menu 3 Select the appropriate channel number for the camera 4 Set CONTROL MODE as HDCVI and set PROTOCOL as HD CVI Figure...

Page 13: ...store the changes 10 Click the right mouse button and select PTZ Control The HDCVI DVR opens the PTZ Setup menu Figure 5 3 11 Click the Camera icon to access the Operation Menu Figure 5 4 Available f...

Page 14: ...ess the camera s settings menu Select a menu item Select a setting value Adjust lens zoom and auto trigger function Adjust lens focus Trigger autofocus at the current zoom factor Available from A1 Sec...

Page 15: ...n cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to outside Change the cloth several times to ensure the dome cover is clean 6 2 Camera Body Use a dry so...

Page 16: ...9 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change without notice Available from A1 Security Camera...

Reviews: