![Dahua 6064 Series Quick Start Manual Download Page 18](http://html2.mh-extra.com/html/dahua/6064-series/6064-series_quick-start-manual_3226650018.webp)
13
Icon
Note
1
~
4
ALARM 1 to ALARM 4. The alarm becomes active in low
voltage.
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4
C4
Four groups of normal open activation output (on/off
button)
GND
1.4.2 Alarm Input Port
Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
Please parallel connect the Ground of the NVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the NVR alarm input(ALARM)
Use the same ground with that of NVR if you use external power to the alarm device.
Figure 1-16
1.4.3 Alarm Output Port
Provide power to peripheral alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model:
JRC-27F
Material of the
touch
Silver
Rating
(
Resistance
Load
)
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Maximum switch voltage
250VAC, 220VDC
Maximum switch currency
1A
Insulation
Between touches with same
polarity
1000VAC 1minute