87
Figure 3-89
Please highlight icon
to select the corresponding function. After setting all the setups please
click save button, system goes back to the previous menu.
3.10.6
Abnormality
There are three types: Disk/Network/power fault.
Disk: Disk error, no disk, no space. See Figure 3-90.
Network: Disconnection, IP conflict, MAC conflict. See Figure 3-91.
Power fault. The interface is shown as in Figure 3-92. This function is for power-redundancy
series product. When this function is on, you can remove one power sourcing from the system, it
does not affect the normal operation of the device, but system will generate an alarm to alert
you.
Alarm output: Please select alarm activation output port (multiple choices).
Less than: System can alarm you when the HDD space is less than the threshold you set here
(For HDD no space type only).
Latch: Here you can set corresponding delaying time. The value ranges from 1s-300s. System
automatically delays specified seconds in turning off alarm and activated output after external alarm
cancelled.
Show message: system can pop up the message in the local screen to alert you when an alarm
occurs.
Alarm upload: System can upload the alarm signal to the network (including alarm centre) if you
enabled current function. For disconnection event, IP conflict event and MAC conflict event, this
function is null.
Send email: System can send out email to alert you when an alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.
Summary of Contents for 600 Series
Page 1: ...Network Video Recorder User s Manual V 5 0 0 ...
Page 86: ...76 Figure 3 73 Figure 3 74 Figure 3 75 ...
Page 94: ...84 Figure 3 83 Figure 3 84 ...
Page 95: ...85 Figure 3 85 Figure 3 86 ...
Page 96: ...86 Figure 3 87 Figure 3 88 ...
Page 98: ...88 Figure 3 90 Figure 3 91 ...
Page 171: ...161 Figure 4 49 Figure 4 50 ...
Page 172: ...162 Figure 4 51 Figure 4 52 ...
Page 179: ...169 Figure 4 61 Figure 4 62 ...
Page 186: ...176 Figure 4 71 Figure 4 72 ...