No. Port Name
Function Description
4
Audio output
Connects to speaker to output audio signal.
5
Alarm I/O
Alarm signal input/output.
For more information about I/O port, see Table 1-2.
Table 1-2
Alarm Information
Port
Port Name
Function
Alarm I/O
ALARM_OUT
Outputs alarm signal to alarm device.
When connecting to alarm device, only the ALARM_OUT port and
ALARM_OUT_GND port with the same number can be used together.
ALARM_OUT_G
ND
ALARM_IN1
Receives the switch signal of external alarm source.
Connect different alarm input devices to the same ALARM_IN_GND
port.
ALARM_IN2
ALARM_IN_GN
D
Connecting Alarm Input/output
1.2
Alarm input/output is available on select models.
Connect alarm input device to the alarm input end of the I/O port, see Figure 1-2.
Step 1
Device collects different states of alarm input port when the input signal is idling and being
grounded.
Device collects logic "1" when input signal is connecting to +3V to +5V or idling.
Device collects logic "0" when input signal is grounded.
Alarm input
Figure 1-2
Connect alarm output device to the alarm output end of the I/O port. The alarm output is
Step 2
open-drain output, which works in the following modes.
Mode A: Level application. Alarm outputs high and low level, and the alarm outlet is OD,
which requires external pull-up resistance (10K Ohm typical) to work. The maximum
external pull-up level is 12V, maximum port current is 300mA and the default output
signal is high level (external pull-up voltage). The default output signal switches to low
level when there is alarm output (As long as the operating current below 300mA, the
output low level voltage is lower than 0.8V).
Summary of Contents for D-IPC-HFW5442EP-ZE-2712-B
Page 1: ...IR Bullet Network Camera Quick Start Guide V1 0 2 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...
Page 13: ...Quick Start Guide 7 Main interface Figure 2 4...
Page 17: ...Quick Start Guide 11 Cable going through the mounting surface...
Page 20: ...Quick Start Guide 14...
Page 21: ...Quick Start Guide...