8.Features
© 2023 China Daheng Group, Inc. Beijing Image Vision Technology Branch 180
2)
Set the "SequencerSetSelector" parameter.
3)
Click "SequencerSetLoad", the values of sequence set parameters are overwritten and replaced by
the values stored in the selected sequence set.
4)
Set the sequence set parameters: ExposureTime, Gain, Gamma, FFC coefficient number, etc.
5)
Click "SequencerSetSave".
Change the number of sequence sets used
By default, sequence set are set as 0->1->2->3...->N−1, but in some cases we may want the sequence
set to run in the order 0->1->2->3->0->1->2->3, in which case this order can be achieved by
"SequencerSetNext".
For example, we want the sequence sets to run in the order 0->1->2->0->1->2, the setting is as follows:
1)
Set the "SequencerSetSelector" to 2.
2)
Set the "SequencerSetNext" to 0.
When acquisition is stopped, the sequence set number is cleared to 0, and when acquisition is
restarted, the sequence set number starts from 0 to perform the sequencer.
Before "SequencerMode" set to "On", the auto gain, auto exposure and auto white balance functions
must be set to "Off".
Sequencer Gain only supports digital gain, not analog
gain.
1)
When "SequencerConfigurationMode" is switched from "Off" to "On", the current value of
"GainSelector" is automatically changed to digital gain.
2)
When "SequencerMode" is switched from "Off" to "On", the current value of "GainSelector" is
automatically changed to digital gain.
3)
When both the "SequencerMode" and "SequencerConfigurationMode" are "Off", the "GainSelector"
function will be restored to be settable, AnalogAll and DigtalAll are selectable. During auto gain
adjustment, only analog
gain is adjusted, digital gain is not adjusted but the setting value is valid.
Sequencer parameters can be saved in user set.
Sequencer parameters do not support remove parameter limits
8.7.3.
Sequence support
Model
Max. sequence
sets number
Sequence support function
MER2-041-528U3M/C(-L)
MER2-160-227U3M/C(-L)
MER2-230-168U3M/C(-L)
MER2-301-125U3M/C(-L)
MER2-502-79U3M/C(-L)
MER2-502-79U3M POL
MER2-1220-32U3M/C(-L)
ME2P-1231-32U3M/C
ME2P-1230-23U3M/C
8
ExposureTime, Gain
Table 8-7 Camera model sequence supported items