background image

It is recommended to clean the aerator of the limescale regularly in 

order to unblock it.

The cleaning of the aerator is very simple - it consists in “pushing out” the 
limescale by pushing in the rubber inset of the aerator (fig. 14). In order to 
extend the life of the heater, there is a filtering sieve placed in the left stub 
pipe of the tap. An excessive increase in the water temperature, a significant 
decrease in the water outflow or lack of outflow may mean the necessity to 
clean the filtering sieve or to replace it.  

It is recommended to install the DAFI mechanical water filter upstre

-

am the DAFI heater

9. Instructions regarding connection to the wiring grid by means of 

the DAFI junction box (available as the additional equipment)

The heaters with the power of 3,7 kW, in accordance with the change intro-

duced  into  EN  60335-2-35/A1:2007,  may  be  connected  to  power  supply, 

using  the  non-disconnectable  power  cable  with  a  socket.  Other  heaters 

should be connected on a permanent basis to the wiring system. For such 

a connection, we can use the DAFI junction box (fig. 15, fig. 16, fig. 17 and 

fig. 18).

a) Insert the body of the junction box (1) into the standard flushed box for the 

auxiliary electrical equipment (2) in accordance with the markings on the box 

(3), then push it so that the body seal (4) could press against the wall on its 

whole circumference and fix it by means of expansion bolts and screws (5) (a 

section without a seal at the bottom of the body (6) 

must remain unsealed, it serves the purpose of di-

scharging the possibly collecting moisture) (fig. 15.).

b) Connect the heater wire (7) with the wires of the 

system (8) using the terminal block (9), fix the wire 

by means of the wire contact (10) and screws (11), 

push in the terminal block with the connected and 

fixed wire into the socket (12) in the body of the box 

(fig. 18). Please pay particular attention to the pro-

per connection of the earthing wire and to provision 

of the proper electrical connection by strong and solid tighte-

ning of the terminals.

c) Place the box cover (13) Slide the cover onto the box from the bottom, 

along the heater wire until the bottom hitches (14) of the cover are slid in 

under the body of the box, then press the cover strongly to the body making 

sure that the dowels in the cover (15) are 

slid into openings (16) in the body of the 

box (fig. 17).

d) In order to remove the cover, slide in 

the slot head screwdriver (17) into the side 

gap between the boxy of the box (1) and 

the cover (13), and turn it by 90o. (fig.18) 

NOTE: In the case of failure to purchase 

fig 14

fig 15

Summary of Contents for IPX4

Page 1: ...ELECTRIC INSTANTANEOUS DAFI WATER HEATER OPERATING INSTRUCTIONS IPX4 IPX5...

Page 2: ...bove 30 l about 83 The DAFI heater is provided with the hygiene certificate of the National In stitute of Hygiene CE certificate of compliance which gives the title to identify the product with the sa...

Page 3: ...nd M 22x1 M 24x1 aera tor reducer is supplied fig 1 a b 3 Construction of the water heater The DAFI heater consists of the heating block placed on the water unit The water unit is made of the base whi...

Page 4: ...cept responsibility for the damage and effects re sulting from unauthorised modifications and repairs of the heater 6 Sequence for connection of the device to the water supply system and the wiring sy...

Page 5: ...llation with the connection and nipples it is recommended to install the DAFI shut off valve at the water inlet to the heater If the valve is included in the set it may be purchased in the retail netw...

Page 6: ...e DAFI heater tap is screwed in fig 11a b reducer shower connector with the M 22 x 1 5 female thread and G 1 2 male thread to which the G1 2 elbow and then the DAFI heater tap are screwed in fig 11b F...

Page 7: ...ut off valve let the necessary water flow through it in order to remove the contamination and air which are present inside the water system Con nect the DAFI heater using the reducing nipples and hose...

Page 8: ...box for the auxiliary electrical equipment 2 in accordance with the markings on the box 3 then push it so that the body seal 4 could press against the wall on its whole circumference and fix it by me...

Page 9: ...iven in these operating instructions ensures proper operation of the DAFI heater NOTE In accordance with the International Safety Standards heating equipment should be subject to periodical surveys ev...

Page 10: ...are not subject to decomposition the equipment does not contain any other hazardous components 3 heating mass about 1 kg At the same time it is announced that in accordance with the regula tions of th...

Page 11: ...alve should be installed on the water inlet line to the DAFI heater All heater units for under sink installation can be installed at any angle Recommendations Installing a composite pipe from your DAF...

Page 12: ...Manufacturer FORMASTER S A 25 818 KIELCE Fabryczna 24 str Poland phone 48 41 3464810 ext 123 fax 48 41 3464870 www formaster com...