background image

main water shut-off valve, turn on the cold water valve of 
the heater tap, letting the necessary water quantity move 
through it in order to remove pollution and air, which are 
present in the water system. 
d) Place the filtering sieve in the left stub pipe of the tap 
(fig. 6.)f) The heater is mounted on two stub pipes (on top 
of the M 18x2 tap), and the spout or sprinkling set is moun-
ted on the bottom end (fig. 7). 
g) Tighten the nuts of the heater uniformly to the tap, avo-
iding the tilting of the heater (fig. 8).
NOTE! 
h) After connecting the heater to the water supply system, 
deaerate the heater by opening the hot water tap valve 
(fig. 9) until the moment of gaining certainty that there is 
no air in the water system.
i) Switch on the power supply ONLY after the prior de-
aeration of the heater as per section 7.1 h (fig. 10)
There is a possibility to install the DAFI water heater on 
the existing wall bathroom tap or kitchen faucet. In lieu of 
the spout, the following items can be screw into the tap:
a) an elbow with M 22 x 1.5 and G ½” female threads to 
which the DAFI heater tap is screwed in (fig. 11a).
b) reducer (shower connector) with the M 22 x 1.5 female 
thread and G 1/2’’ male thread, to which the G1/2” elbow 
and  then  the  DAFI  heater  tap  are  screwed  in  (fig.  11b). 
Further installation operations are the same as in the case 
of installation of the heater at the end of the water supply 
pipe running out of the wall.

7.2 Installation of the heater with the connection

In case of installation of the heater with the connection, use 
only the DAFI heater with the degree of protection against wa-
ter penetration - IPX4 (fig. 12).  
In  this  system,  the  connection  should  be  preceded  by  the 
DAFI shut-off valve (fig. 13). 
In order to install the heater with the connection, the connecting 
element, which is mounted on the pipe that supplies water is 
used instead of the tap with the spout. 
Before the installation of the heater, install the shut-off valve 
on the pipe and let the necessary water through it in order to 
remove the contaminants and the air, which are present in the 
water system. 
Install the connection and fix the DAFI water heater to it. During 
this activity, it is important to supply the cold water into the stub 
pipe of the heater in accordance with the marking (arrows) at 

fig 2

fig 3

fig 4

fig 5

fig 6

fig 7

fig 8

Summary of Contents for IPX4

Page 1: ...ELECTRIC INSTANTANEOUS DAFI WATER HEATER OPERATING INSTRUCTIONS IPX4 IPX5...

Page 2: ...bove 30 l about 83 The DAFI heater is provided with the hygiene certificate of the National In stitute of Hygiene CE certificate of compliance which gives the title to identify the product with the sa...

Page 3: ...nd M 22x1 M 24x1 aera tor reducer is supplied fig 1 a b 3 Construction of the water heater The DAFI heater consists of the heating block placed on the water unit The water unit is made of the base whi...

Page 4: ...cept responsibility for the damage and effects re sulting from unauthorised modifications and repairs of the heater 6 Sequence for connection of the device to the water supply system and the wiring sy...

Page 5: ...llation with the connection and nipples it is recommended to install the DAFI shut off valve at the water inlet to the heater If the valve is included in the set it may be purchased in the retail netw...

Page 6: ...e DAFI heater tap is screwed in fig 11a b reducer shower connector with the M 22 x 1 5 female thread and G 1 2 male thread to which the G1 2 elbow and then the DAFI heater tap are screwed in fig 11b F...

Page 7: ...ut off valve let the necessary water flow through it in order to remove the contamination and air which are present inside the water system Con nect the DAFI heater using the reducing nipples and hose...

Page 8: ...box for the auxiliary electrical equipment 2 in accordance with the markings on the box 3 then push it so that the body seal 4 could press against the wall on its whole circumference and fix it by me...

Page 9: ...iven in these operating instructions ensures proper operation of the DAFI heater NOTE In accordance with the International Safety Standards heating equipment should be subject to periodical surveys ev...

Page 10: ...are not subject to decomposition the equipment does not contain any other hazardous components 3 heating mass about 1 kg At the same time it is announced that in accordance with the regula tions of th...

Page 11: ...alve should be installed on the water inlet line to the DAFI heater All heater units for under sink installation can be installed at any angle Recommendations Installing a composite pipe from your DAF...

Page 12: ...Manufacturer FORMASTER S A 25 818 KIELCE Fabryczna 24 str Poland phone 48 41 3464810 ext 123 fax 48 41 3464870 www formaster com...

Reviews: