15
Page 1: ...em Flow Comfort DC10 Lead Brand most frequently recommended and purchased among water filtering products Source Formaster S A based on a survey conducted by Difference nationwide sample of N 1000 peop...
Page 2: ...em Instalation Turning on the system Replacement of the D10 Lead filter cartridge Maintenance Filter Replacement Indicators Flow Meter User s Manual Technical specifications of the Flow Meter Instruct...
Page 3: ...g valve must be installed Certain groups of people e g people with kidney diseases or weak immune system should con sult the possibility and method of use of the filter with a specialist and or a phys...
Page 4: ...ing the instruc tions in this ma nual In case of any doubts difficulties or lack of proper tools the connection of the system should be entrusted to a certified specialist Before the installation of c...
Page 5: ...oosely led out and be outside of the head Press the head onto the filter cartridge in a firm motion pressing the entire surface evenly so that no gap remains between the filter and the head When insta...
Page 6: ...ed for 6 3 mm water hoses on the water intake Angular stop valve with a check valve 3 8 thread and quick release coupling for a 1 4 water hose allows snapping the 1 4 water hose in the place of connec...
Page 7: ...7 Examples of connection...
Page 8: ...of the D10 Lead filter cartridge Replacement of the D10 Lead filter cartridge The water filter must be replaced if at least one of the following situations happens The taste or smell of filtered wate...
Page 9: ...RESET Filter Replacement Indicators The integrated indicator faucets VITO HERO RESET Button to reset and activation of work indicator LED SIZE HRD signaling diode of type of cartridge and hardness le...
Page 10: ...s you have 7 days to replace the filter car tridge red blinking diode and 3 series of beeps every 1 hour replace the filter cartridge with a new one when the reminder on the need to replace the filter...
Page 11: ...r monitoring is 99999 liters Completion of programming the meter will signal with a beep If no button is pressed for one minute during programming the procedure will be terminated and the meter will r...
Page 12: ...mixed solid waste since it is classified as waste that can be harmful to the environment The user is obligated to hand over the used device to a point of selective collection of electrical equipment...
Page 13: ...s was not replaced at the right time The warranty will become invalid when damage results from situations described in section 6 The warranty does not cover mechanical interference alterations or othe...
Page 14: ...14...
Page 15: ...15...
Page 16: ...Manufacturer Dafi LLC 601 N Congress Ave Ste 201 Delray Beach FL 33445 e mail support dafi us tel 561 717 6782 2023_xxx_xx Data wykonania 07 07 2023 roku Wersja 2_DC10...