3. Operation
VMCTOPES8D51
1. It is impossible to do cycle start without all axes reference return after NC power
is off/on.
That case you have to change parameter MD20700 to “0”.
2. Parameter MD20700 must set to “1” after maintenance is finished.
CAM ATC INTERLOCK
ATC ERROR Reset and driving condition
When ATC changer arm
is not in home position
during tool change,
power OFF or emer-
gency stop is occured.
(When MACHINE
READY is off)
(When NC is off)
1
Remove tools in spindle and waiting pot or Grippers
2
Command M39 in MDI mode
3
Select JOG mode in Main OP. device
4
Select Manual mode in ATC OP. device
5
Move ATC changer arm to home position by pushing CW or CCW
buttons of ATC OP. device
6
Select Auto mode in ATC OP. device
7
Select MDI mode in Main OP. device
8
Command M41
9
Check tool list
Please check waiting pot number and spindle tool number
- Zaxis cannot be move under ATC interlock state
3 – 30
Inspection/adjustment/maintenance