Daewoo KQG-63N75S Service Manual Download Page 21

20

3. COMPONENT TEST PROCEDURE

 High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.
 It is neither necessary nor advisable to attempt measurement of the high voltage.
 Before touching any oven components or wiring, always unplug the oven from its power source and discharge the

capacitor.

1. High voltage transformer

(1) Remove connections from the transformer terminals and check continuity.
(2) Normal readings should be as follows:

Secondary winding ...................Approx. 110   10%
Filament winding....................................Approx. 0
Primary winding .....................................Approx. 1

2. High voltage capacitor

(1) Check continuity of capacitor with meter on the highest OHM scale.
(2) A normal capacitor will show continuity for a short time, and then indicate 10M

once the capacitor is charged.

(3) A shorted capacitor will show continuous continuity.
(4) An open capacitor will show constant 10M .
(5) Resistance between each terminal and chassis should be infinite.

3. High voltage diode

(1) Isolate the diode from the circuit  by disconnecting the leads.
(2) With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals.

Reverse the meter leads and again observe the resistance reading. 
Meter with 6V, 9V or higher voltage batteries should be used to check the front-back resistance of the diode, oth-
erwise an infinite resistance may be read in both directions. 
A normal diode s resistance will be infinite in one direction and several hundred K

in the other direction.

4. Magnetron

For complete magnetron diagnosis, refer to  Measurement of the Microwave Power Output .
Continuity checks can only indicate and open filament or a shorted magnetron. 
To diagnose for an open filament or a shorted magnetron.

(1) Isolate magnetron from the circuit by disconnecting the leads.
(2) A continuity check across magnetron filament terminals should indicate 0.1

or less.

(3) A continuity check between each filament terminal and magnetron case should read open.

5. Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor
switch before replacing the blown fuse.
In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time.
Replace just the fuse if the switches operate normally.

20

Summary of Contents for KQG-63N75S

Page 1: ...3N75S001 http svc dwe co kr Jan 2004 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information pleas...

Page 2: ...s d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this...

Page 3: ...ertified oven unit is found to servicing a microwave emission check should be performed prior to servicing the oven a inform the manufacturer importer or assembler b repair the unit at no cost to the...

Page 4: ...OMBINATION 2200 W MICROWAVE ENERGY OUTPUT 800W MICROWAVE FREQUENCY 2450MHz OUTSIDE DIMENSIONS W x H x D 465 x 279 x 360mm CAVITY DIMENSIONS W x H x D 290 x 208 x 306mm NET WEIGHT APPROX 14Kg TIMER 35...

Page 5: ...nter of the ovens cavity floor This is to remain in the oven for all cooking 10 Roller guide This must always be used for cooking together with the glass cooking tray 11 Glass cooking tray Made of spe...

Page 6: ...t be repaired with cable of same type Such a cable can be purchased from DAEWOO and must be installed by a Qualified Person 6 Examine the oven after unpacking for any damage such as A misaligned door...

Page 7: ...r microwave oven is fitted with safety door interlock switches If you wish to inspect the food during the cooking time simply open the door The oven will automatically stop cooking To continue cooking...

Page 8: ...ir work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing or c...

Page 9: ...SCREEN O TEMP GLASS T3 2 MIRROR 1 A03 3515204100 STOPPER HINGE T AS KOR 63150S 1 A04 3511706120 DOOR PAINTING AS KOR 634R0S 1 A05 3517002800 BARRIER SCREEN I POLYESTER T0 1 1 A06 3512300210 GASKET DO...

Page 10: ...on stopper hinge under and then push the door to contact the door seal to oven front surface Tighten two screws NOTE A small gap may be acceptable if the microwave leakage does not exceed 4mW cm2 1 Re...

Page 11: ...513407310 KNOB SLIDE ABS SG 175 SG 0760D 1 B18 3515101600 SPRING FLAT SUS 301 T0 5 1 5 To remove control panel parts 1 Remove the screw which secure the control panel push two snap fits and draw forwa...

Page 12: ...for a fully assembled oven with door normally closed 6 To remove high voltage capacitor 1 Remove a screw which secure the grounding ring terminal of the H V diode and the capacitor holder 2 Remove th...

Page 13: ...sembly 4 Draw forward the wind guide assembly 5 Pull the fan from the motor shaft 6 Remove two screws which secure the motor shaded pole 7 Remove the motor shaded pole 8 Reverse the above steps for re...

Page 14: ...ew which secure the tray motor 6 Remove the tray motor 7 Reverse the above steps for reassembly except for secur ing the tray motor cover with screw 11 To remove heater assembly 1 Remove one side of t...

Page 15: ...T1 TRS 4X10 MFZN 2 C03 3510607800 BRACKET HEATER T SBHG T0 5 2 C04 3512803700 HEATER MIRACLON 115V AC 500W 2 C05 3511408100 COVER HEATER T STS430 T0 5 1 14 Caution In this Service Manual some parts ca...

Page 16: ...pushes the lock lever downward The lock lever presses the button of the interlock monitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it und...

Page 17: ...es the fan motor work when you shut the door and turn the timer YES If outlet has proper voltage check continuity of power supply cord Replace power supply cord NO Continuity Check continuity of inter...

Page 18: ...ble motor NO If microwave do not oscillate check continuity of filament of magnetron Poor continuity NO Continuity Check continuity filament tap 3 3V of high voltage Replace high Voltage transformer N...

Page 19: ...water to the vessel the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microwave power is switched on 5 Heating time should be exactly A seconds Refer...

Page 20: ...t door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cabinet door seem is...

Page 21: ...r set on the highest resistance scale measure the resistance across the diode terminals Reverse the meter leads and again observe the resistance reading Meter with 6V 9V or higher voltage batteries sh...

Page 22: ...WIRING DIAGRAM 21...

Page 23: ...ly and assembly 3 TOTAL ASSEMBLY EXPLODED VIEW AND PARTS LIST F54 F53 F52 F51 F15 F11 F13 F12 F14 F16 C00 F44 F05 F06 F50 F49 F42 F41 F40 F39 F38 F37 F36 F35 F34 F33 F25 F24 F23 F22 F21 F04 F02 F03 F0...

Page 24: ...O F27 7112401011 SCREW TAPPING T1 TRS 4 10 MFZN O F28 3512100900 FOOT PP DASF 130 O F29 7272400811 SCREW TAPTITE TT3 TRS 4X8 MFZN O F30 3515201101 STOPPER HINGE U SCP 1 T2 5 O F31 7122401211 SCREW TAP...

Page 25: ...S M NO G63N75S001 DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Jan 2004...

Reviews: