21
2. MICROWAVE RADIATION TEST
PROCEDURE
1. Prepare Microwave Energy Survey Meter, 600cc glass beaker, and glass
thermometer 100
℃
( 212
℉
).
2. Pour 275cc
±
15cc of tap water initially at 20
±
5
℃
(68
±
9
℉
) in the 600
cc glass beaker with an inside diameter of approx. 95mm(3.5 in.).
3. Place it at the center of the tray and set it in a cavity.
4. Close the door and operate the oven.
5. Measure the leakage by using Microwave Energy Survey Meter with dual
ranges, set to 2450MHz.
1) Measured radiation leakage must not exceed the value prescribed below.
Leakage for a fully assembled oven with door normally closed must be
less than 4mW/
㎠
.
2) When measuring the leakage, always use the 5
㎝
(2 in.) space cone with
probe. Hold the probe perpendicular to the cabinet and door. Place the
space cone of the probe on the door, cabinet, door seem, door viewing
screen, the exhaust air vents and the suction air vents.
3) Measuring should be in a counter-clockwise direction at a rate of 1 in/sec. If
the leakage of the cabinet door seem is unknown, move the probe more slowly.
4) When measuring near a corner of the door, keep the probe perpendicular to the areas making sure the probe end at the base of
the cone does not get closer than 2 in. from any metal. If it does not , erroneous reading may result.
WEIGHT TIME START
DEFROST
STAGE
AUTO
LOCK NO CUP g
Auto Cook
1. Raked Potato
2, Fresh Vegetable
3. Soup
4. Fish Fillets
5. Meat Loaf
Menu
Weight
Auto Def.
Beverage
popcorn
Muffin
Frozen
Pizza
Dinner
Plate
Power
Clock / A.Start
Speedy Cook
Feeding
Bottle
1
2
3
4
5
6
7
8
9
0
Stop/Clear
Start
1 2
CAUTION
1. Make sure to check the microwave leakage before and after repair of adjustment.
2. Always start measuring of an unknown field to assure safety for operating personnel from microwave energy.
3. Do not place your hands into any suspected microwave radiation field unless the safe density level is known.
4. Care should be taken not to place the eyes in direct line with the source of microwave energy.
5. Slowly approach the unit under test until the radiometer reads an appreciable microwave leakage from the unit under the
test.