background image

The battery is working for the carburetor valve at “RUN” channel. So please make sure the switch is 
at the “OFF” channel when the unit is turn off.

2) Fuel valve

The fuel valve is used to control the fuel flow from the tank to the carburetor. After stopping the 
engine, the fuel valve should turn to “Off” position.

3) Choke button

The choke button is used to provide mixed gas with rich fuel to the engine when it is in cold start. 
When the engine runs normally, push it to “open” position.

4) AC circuit breaker

The overload current will make the circuit breaker trip out automatically. It is required to prevent the 
generator set from short circuit or overload. If the circuit breaker drips out, do not turn on the circuit 
breaker before checking the load and short  circuit.

On

Choke

Fuel valve

On

Off

3 phase

Circuit
breaker

1 phase

Circuit
breaker

Off

5

Summary of Contents for GDA15000E

Page 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL GDA15000E Gasoline generator...

Page 2: ...AMES 4 4 OPERATION SYSTEM 4 5 USE OF GENERATOR 6 6 CHECK BEFORE OPERATION 8 7 START ENGINE 10 8 STOPPING ENGINE 11 9 MAINTENANCE SCHEDULE 11 10 STORAGE 14 11 TROUBLESHOOT 16 12 WIRING DIAGRAM 17 13 PO...

Page 3: ...will occur provided your operation does not follow the information after the symbol CAUTION Slight harm will occur provided your operation does not follow the information after the symbol NOTE Damage...

Page 4: ...Never connect it direct to power supply Keep it 1m away from inflammable thing Don t smoke while filling fuel Don t overfill fuel Stop engine before filling fuel 3...

Page 5: ...e in Run position OFF indicates the engine in OFF position START indicates the engine in starting position Frame Fuel tank Break protector Digital voltmeter The socket Earthing terminal Walk round Eng...

Page 6: ...The choke button is used to provide mixed gas with rich fuel to the engine when it is in cold start When the engine runs normally push it to open position 4 AC circuit breaker The overload current wi...

Page 7: ...ause of lack of oil 5 USE OF GENERATOR Environmental requirement for use of the generator Serviceable temperature 15 C 40 Serviceable humidity 95 below Serviceable elevation in area below 1000 m If us...

Page 8: ...loaded use will shorten the service life of the generator set Keep firmly in mind that if the generator set connects with several loads or appliances it is recom mended to turn on the appliance with t...

Page 9: ...carburetor for high elevation is used in low elevation area the situations of engine power degraded engine overheated or engine damaged severely may occur because of rarefied mixed gas 6 CHECK BEFORE...

Page 10: ...filler cap the cap on the head facing to the ruler and fill the recommended oil till it goes up to the top limit After filling oil keep firmly in mind to reinstall the ruler and tighten the cap 2 Fuel...

Page 11: ...it will damage the engine and battery severely Check the electrolyte level in cell if they are in the position between the top limit line and low limit line If the electrolyte level is lower the low...

Page 12: ...8 STOPPING ENGINE 1 Turn off the AC circuit breaker 2 Turn off the engine switch 3 Close the fuel valve NOTE If an emergency stop is necessary turn off the engine switch directly 9 MAINTENANCE SCHEDU...

Page 13: ...ing with troubles will cause harmful default Please check the generator in accordance with the manual instruction and maintain it in time 1 Replace engine oil After warming up the engine it is easy to...

Page 14: ...the cap nut and remove the case 2 Remove the washer take out the paper and foam elements 3 Separate the paper element from the foam one 4 Check the elements and replace if necessary As a rule when re...

Page 15: ...crew the spark plug with hand carefully to avoid damaging the thread on the head 6 When the spark plug is in position tighten the spark plug with the special socket wrench and depress the washer If in...

Page 16: ...the draining screw fill fresh oil to the top line then reinstall the ruler 3 Remove two spark plugs fill 5 lm 10 lm oil a spoon of oil in the combustion chamber Rotate the crankshaft in several turns...

Page 17: ...el in carburetor Contact with authorized dealer Conctact with authorized dealer Check and clean depositing cup Check if breaker is in off position No voltage No No No No No No No Yes Yes Check if ther...

Page 18: ...12 WIRING DIAGRAM 1 1500 1 phase diagram 17...

Page 19: ...sening the wire remove the wire from the negative terminal then remove it from the positive one 14 TECHNICAL SPECIFICATIONS Engine type 2 Cylinders 4 Stroke Forced air cooling Engine speed 3600 rpm Ra...

Page 20: ...r more nodes teaser on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation...

Page 21: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea...

Reviews: