14
EN
GDA
3500
/
3500
E /
3500
DFE /
6500
/
6500
E /
7500
E /
7500
E-
3
GDA
7500
DPE-
3
/
7500
DFE /
8500
E /
8500
E-
3
/
9500
DPE-
3
TROUBLESHOOTING
Malfunction
Possible cause
Action
Engine doesn’t start
Engine switch in OFF
Put engine switch ON
Fuel cock is in CLOSED position
Put the fuel valve to the OPEN
position
Choke lever is opened
Close the lever
No fuel in the engine
Fill in with fuel
Engine contains dirty or old fuel
Change the fuel in the engine
The spark plug is smoky or
damaged; wrong distance between
electrodes
Clean spark plug or replace; set the
distance between the electrodes
Difficulty starting or
reduced engine power
Fuel tank is dirty
Clean the fuel tank
Air filter is dirty
Clean the air filter
Water in the fuel tank and
carburetor; carburetor clogged
Empty the fuel tank; clean the fuel
line and carburetor
Incorrect electrode gap in spark
plug
Set the electrode gap
The engine overheats
Air filter is dirty
Clean the air filter
Cooling fins are dirty
Clean the cooling fins
Engine starts but no
output voltage
Circuit breaker tripped
Put circuit breaker ON
Bad connection cables
If an extension cord is used,
replace it
Faulty connected electrical device
Try connecting another device
Generator runs but
does not support
connected electrical
devices
Generator overload
Try to connect fewer devices
Short circuit on one of the
connected devices
Try to disconnect failed device
Air filter is dirty
Clean the air filter
Insufficient engine speed
Contact an Authorized Service
Center
Summary of Contents for GDA 3500
Page 75: ...71 DAEWOO POWER COM 1 15 40 95 1000 3 1 3 min...
Page 79: ...75 DAEWOO POWER COM DF 3 4 1 1 2 4 2 GDA 7500DFE GDA 3500DFE 5 OFF 10 5 6 6 1...
Page 81: ...77 DAEWOO POWER COM 10 50 11 F6RTC NGK BPR6ES 0 7 0 8 5 10...
Page 83: ...79 DAEWOO POWER COM ON...
Page 169: ......
Page 170: ...Manufactured under license of DAEWOO International Corporation Korea WWW DAEWOO POWER COM 1...