16
- If the temperature of refrigerator compartment is weak or insufficient,
you can compensate the on/off temperature by cutting jump wire of main PCB.
(temperature down)
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Main PCB
Resistance of R-sensor
4-9. Temperature compensation (Refrigeration compartment)
R
R
-
-
Sensor
Sensor
J2
R36
R37
R38
J1
Refer to the 5-2.
(Function of each sensor)
J1
J2
< Location of R-sensor at Main-PCB >
< Circuit diagram of R-sensor>
- If need to compensate
Compensation
(weak-cool)
R36 + R37 + R38
R36 + R37
R36
Resistance
cut
-
-
J2
cut
cut
-
J1
3C
down
1.5C
down
Normal
condition