15
1. How to start
1) Under “Lock” condition,
Press and hold “Refrigerator” button and press “Dispenser” button 5 times simultaneously.
2. How to control
1) All other electrical components are OFF except for F-Fan & R-Fan
2) Fan Control
Door opened - Fan ON
Door closed - Fan OFF.
3. How to exit
1) Under “Demonstration” mode,
Press and hold “REF Set” button and press “Dispenser” button 5 times simultaneously.
2) or power reset.
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. “Refrigerator” & “Dispenser” Button
Comp
F/R-Fan
Heater
4-8. Demonstration